Operation Manual

Technical specifications | 41
Figure 4-5 AC12/AC42 Cable retainer
4.5 FC40 Fluxgate Compass
Dimensions: ..................................................... See Figure 4-6
Weight: .......................................................... 0,9 kg (2,0 lbs)
Material: ................................................................ Black ABS
Environmental Protection: ................................................ IP56
Temperature range:
Operation: ....................... 0 to +55 °C (+32 to + 130 °F)
Storage: ........................ 30 to +70 °C (22 to +158 °F)
Supply and interface: .................................... 8-16V via SimNet
Power consumption: ...................................................... 1,4 W
SimNet Network load factor (NL): .......................................... 3
SimNet ports (input/output): ................................................ 1
Cable supplied: ............ 5.5 m (18’) SimNet cable with connector
Mounting: .................................................... Deck or bulkhead
Automatic Performance:
Calibration: ...... Automatically activated from control head
Gain control: ............. Automatically adjusted continuously
Deviation control: .......................................... Automatic
Static Performance:
Roll/Pitch: ........................................................... 35°
Accuracy: ....................................... 3° after calibration
Repeatability: ..................................................... 1.0°