Instruction manual
Table Of Contents
- SIMRAD AP35 AUTOPILOT
- DOCUMENT HISTORY
- 1 GENERAL INFORMATION
- 2 OPERATION OF THE AUTOPILOT
- 2.1 Overview
- 2.2 ON/OFF - Standby mode
- Follow-Up steering
- 2.4 Non-Follow-Up steering
- 2.5 NFU Steering lever
- 2.6 NFU Push button remote control
- 2.7 R3000X Remote Control
- 2.8 S35 NFU Steering Lever
- 2.9 Automatic Steering
- 2.10 Automatic Speed selection
- 2.11 Manual speed selection
- 2.12 Navigating with the AP35
- 2.13 WORK-mode
- 2.14 TURN-mode
- 2.15 Dodging
- 2.16 Multiple station system
- 2.17 Lock function
- 2.18 User Set-up Menu
- 3 TECHNICAL SPECIFICATIONS
- 3.1 AP35 Autopilot System
- 3.2 AP35 Control Unit
- 3.3 Junction units
- 3.4 RFC35 Fluxgate compass
- 3.5 RC25 Rate Compass
- 3.6 CDI35 Course Detector Interface
- 3.7 RI35 Mk2 Rudder Angle Indicator
- 3.8 RF300 Rudder Feedback Unit
- 3.9 RF45X Rudder Feedback Unit
- 3.10 R3000X Remote
- 3.11 GI51 Gyro Interface
- 3.12 NI300X NMEA Interface
- 3.13 S35 NFU Steering Lever
- 3.14 FU50 Steering Lever
- 3.15 IP protection
- 4 INSTALLATION
- 4.1 General
- 4.2 Installation checklist
- 4.3 Unpacking and handling
- 4.4 Determine system configuration
- 4.5 AP35 System Layout
- 4.6 RF300 Rudder feedback
- 4.7 RF45X Rudder Feedback Unit
- 4.8 Junction unit
- 4.9 Drive unit
- 4.10 Control unit
- 4.11 RFC35 Fluxgate Compass
- 4.12 RC25 Rate Compass
- 4.13 R3000X Remote Control
- 4.14 FU50 Steering Lever
- 4.15 S35 NFU Steering Lever
- 4.16 F1/2 Remote Control
- 4.17 RI35 Mk2 Rudder Angle Indicator
- 4.18 Interfacing
- 4.19 Single NMEA input/output
- 4.20 Double NMEA input/output
- 4.21 Additional NMEA output on Port 2
- 4.22 Input from “NMEA Compass”
- 4.23 Radar Clock/Data
- 4.24 IS15 Instrument
- 4.25 Analog Repeater
- 4.26 Digital Repeater
- 4.27 External Alarm
- 4.28 NI300X NMEA Interface Unit
- 4.29 CI300X Compass Interface
- 4.30 GI51 Gyro Interface
- 4.31 CD100A Course Detector
- 4.32 CDI35 Interface
- 4.33 Software Setup Procedure
- 4.34 Sea Trial
- 4.35 Final sea trial
- 4.36 Providing user training
- 5 MAINTENANCE
- 6 TROUBLE SHOOTING
- 7 SPARE PARTS LIST

Installation
22083083K 49
Main Board terminals
4.9 Drive unit
The relation between drive units, drive unit voltage, input voltage, drive
output and interfacing to steering gear are shown in the table below. The
AP35 system detects whether a reversible motor or a solenoid is connected
and outputs the correct drive signal automatically.
Refer to the connecting diagram for the different drive units on page
51
onwards.
Installation instructions for the drive units are found in the manual for the
individual units.
The maximum drive current capabilities of the J3000X and J300X junction
units are different. Use the table below as reference.
HYDRAULIC PUMPS
RAM CAPACITY
MODEL MOTOR
VOLTS
JUNCTION
UNIT
MIN
cm
3
(cu. in.)
MAX
cm
3
(cu. in.)
FLOW
RATE AT 10
bar
cm
3
/min
(cu. in/min)
MAX
PRES-
SURE
bar
PWR.
CONSUMP-
TION
RPU80 12V J3000X 80 (4,9) 250 (15,2) 800 (49) 50 2,5-6 A
RPU160 12V J300X 160 (9,8) 550 (33,5) 1600 (98) 60 3-10 A
RPU300 12V J300X-40 290 (17,7) 960 (58,5) 3000 (183) 60 5-25 A
RPU300 24V J300X 290 (17,7) 960 (58,5) 3000 (183) 60 2,5-12 A
Steering gear interface: Hydraulic plumbing