Installation manual
Installation
20222469 / B 17
Refer to the table below for recommended cable sizes.
Cable length Drive Unit Voltage
1. Distribution Board to Junction Unit. 12 V 24 V
2. Junction Unit to Drive Unit motor
(Length refers to each of the two cables)
mm
2
AWG mm
2
AWG
Up to 3 m (10 ft.) 2,5 12 2,5 12
Up to 6 m (20 ft.) 4 10 2,5 10
Up to 10 m (32 ft.) 6 8 4 10
Up to 16 m (52 ft.) 10 6 6 8
Table 2-1 Recommended Cable Sizes
Grounding and Radio Frequency Interface
(RFI)
The AP50 system has excellent radio frequency interference
protection and all units use the junction unit as a common
ground/shield connection. The junction unit must therefore have
a proper ground connection to the hull.
Robnet cables and other signal cables (i.e. compass, feedback,
NMEA) should not be run in parallel with other cables carrying
radio frequency or high current, such as VHF and SSB
transmitters, battery chargers/generators, and winches.
Figure 2-12 J50 Junction Unit Screen Termination
Remove the bottom cover to get access to the plug-in terminals.
Strip about 1 cm (0.4 in.) of the cable's insulation and pull the
screen backwards to cover the insulation. Position the straps as
shown and tighten well to make sure the screen makes good
contact.
Ground terminal
Note!
The Mains input
is not polarity
p
rotected on the
J
50-40.