Installation manual

Simrad AP50 Autopilot
38 20222469 / B
2.20 F1/2 Remote Control
The F1/2 Remote Control comes with 10 m (33 ft.) of cable and
is connected to the junction unit as shown in Figure 2-36.
F1/2
REMOTE CONTROL
NOTE!
Disregard the color code
on the terminal label.
REMOTE
JUNCTION UNIT
POWER PCB
TB1
TB2
TB3
TB5
Violet
Brown
Beige
REMOTE
TB4
Stbd
Port
Gnd
Figure 2-36 F1/2 Remote Control Connection
2.21 Interfacing to Optional Equipment (THD,
Navigation Receiver, etc.)
With the AP50 autopilot system, there are several options for
connection to other equipment for data exchange:
1. The J50 Junction Unit includes two NMEA input/output ports
and a Clock Data heading interface to Simrad and Furuno
radars. Only the J50-2 port (NMEA input 2) accepts NMEA
heading sentences.
2. The optional NI300X NMEA Interface (expansion) Unit
includes 4 additional NMEA input/output ports.
The following connecting diagrams illustrate the interfacing
possibilities.
Note ! See also “Interface Set-up” page 54 and the NMEA sentence
table page 109.