control units in a master station, but only one of them can be set as the Master unit.
All units included in the master station will be unlocked, and command transfer within the
master group will be as in an open system.
Units not included in the master station will be locked. It is not possible to take command
from units outside the master station unless the master control unit opens for this. All units
outside the master station will have a lock symbol.
In the illustration below the main bridge is defined as master station. One QS80, one AP80
control unit and one AP70 control unit are included in the master station. The AP80 control
unit is defined as the Master unit.
The illustration includes SimNet group settings for each unit, showing how the units are
defined as part of different SimNet stations.
WING STATION
AFT STATION
MAIN BRIDGE
Dening a Master system
A master station is usually defined and units assigned to the master station during system
setup.
¼ Note: When a SimNet group Station is set to Master, one control unit in this steering station
has to be defined as the Master unit as shown below.
Damping
Controls how quickly the display updates values from sensors.
Increasing the damping applies more averaging or smoothing of the data update rate on the
display.
Damping settings are applied to SimNet units belonging to particular damping SimNet
Groups.
¼ Note: If the damping factor for heading is high, the captured heading might differ from the
heading read on the display when using the heading capture function.