Service manual

Simrad EA 500 / EK 500
P2265E/F 9
3.2 LIST OF SIGNAL PROCESSOR ERROR MESSAGES
Note that the # sign indicates transceiver number (1/2/3) and that all error
messages end with "error".
Error message Legal values
SP-# angle sensi. error 0 to 100 el./mech.
SP-# bandwidth error 0 to 1
SP-# beamtype error 0 to 1
SP-# btm. min. level error -80 to 0 dB
SP-# btm. max. depth error 0 to 20000 m
SP-# btm. min. depth error 0 to 1000 m
SP-# damping coeff. error 0 to 300 dB/km
SP-# device data error See note I
SP-# equ. beam angle error -100 to -1 dB
SP-# FIFO input error 0 to 1
SP-# frequency error 10
4
to 10
6
Hz
SP-# heave conver. error -10 to 10 V/m
SP-# layer data error See note III
SP-# noise margin error 0 to 40 dB
SP-# not responding error See paragraph 3.1
SP-# ping mode error 0 to 3
SP-# pitch conver. error -10 to 10 V/m
SP-# product type error 0 to 1
SP-# pulse length error 0.02 to 10 ms
SP-# roll conver. error -10 to 10 V/m
SP-# sample interval error 0.005 to 0.5 m
SP-# sound velocity error 1400 to 1700 m/s
Sample tg error 0 to 1
FIFO tg error 0 to 1
SP-# transceiv. mode error 0 to 3
SP-# transceiver HW error
SP-# transd. depth error 0 to 1000 m
SP-# transd. seq. error
SP-# transd. param. error See note II
SP-# transd. gain error 1 to 100 dB
SP-# transmit power error 0 to 10 kW
SP-# TS phasedevia. error 0 to 10
SP-# TS min. level error -100 to 0 dB