Technical data

Instruction Manual
19
E03766 Issue 3.0
3.7 Troubleshooting
These simple checks should be carried out before seeking tech-
nical assistance and may save time and expense.
Before contacting your servicing agent, please obtain the
radio’s serial number and the software iteration – this is shown
in the large digits on the display for 2 seconds after the radio is
turned on.
Symptom Possible cause Remedy
Unit will not switch on • Battery not charged • Re-charge battery
• Battery not attached correctly • Ensure battery is fully
to radio engaged (refer to
section 2.5)
Scan or Memory Scan • Noise on the channel is • Increase squelch level
is locking on a channel holding the scan • Inhibit channel from
without a signal scan
Dual Watch not being • Priority channel selected Select a working
entered (normally channel 16) channel
Cannot change channel • Dual Watch (D/W) engaged • Exit Dual Watch
Certain channel numbers • Some channels are restricted • Consult your national
are not obtainable and programmed depending authority for permitted
on country of purchase channels in your region
Will not transmit Scanning or D/W function active Exit D/W or scan
Will not transmit on 5W Low voltage when full transmit- Battery charge low –
but OK on 1W ting current is drawn recharge the battery
• Some channels are restricted to • Consult your national
low power transmission only authority
Transmissions are • Damaged antenna • Replace antenna
persistently weak