Technical information

Functionsanddialogs
Description
TheEK60software
automaticallyscansthe
computertolocateand
identifyEthernet(LAN)
andseriallineinterfaces.
Oncethesoftwarehas
establishedalistofvalid
interfaces,youcansetup
andcontroltheparameters.
ThePortManagement
dialogprovidestwolists,
oneforserialportsand
oneforEthernet(LAN)
ports.Youcanaddand
deleteportsaspermittedby
theinterfaceresourcesprovidedbythecomputer,andyoucandenecommunication
parametersforeachindividualport.
PortManagement;Serialportsonpage119
PortManagement;LAN(Ethernet)portsonpage121
Relatedtopics
Installmenu;functionsanddialogsonpage95
SerialPortSetuponpage169
LANPortSetuponpage168
PortMonitoronpage170
PortManagement;Serialports
Parameters
1SerialPorts
Thislistdisplaystheavailableserialportsonthecomputer.
ThelistisautomaticallypopulatedthersttimethePortManagementdialogis
openedafteraEK60softwareinstallation,andwillthenreecttheinitialnumberof
serialportsavailableonthecomputer.Ifyoulateraddinterfacehardwaretoyour
computer,youmustclicktheAddbuttontoaddthenewportstothelist.
Ablue
backgroundonalistedportmeansthattheportiscurrentlyselected.
Agreen
backgroundonalistedportmeansthattheEK60softwarehastested
andacknowledgedthisportforuse.
Ared
backgroundonalistedportmeansthattheEK60softwarehastestedthe
port,butithasfailedtowork.Theportmaynotbephysicallypresent,oranother
programonthecomputerhasallocatedit.
Awhite
backgroundonalistedportmeansthattheEK60softwarehasnotyet
testedtheport.
164692/D
119