Technical information
Functionsanddialogs
Description
TheAnalogMotionSensorSetupprovides
sensitivityandoffsetvaluesforheave,roll
andpitch.Eachparametercanbeselected
individually.
Example5Offsetparameters
Ifthesensoroutputsaxedvoltage
whenthevesselislevelandnot
moving,youcanadjusttheoffsetso
thattheEK60acceptsthisinputasthe“normal”value.
Parameters
1HeaveVoltageSensitivity
Adjustthesensitivityfromthesensor.
2HeaveVoltageOffset
Adjusttheoffsetlevelsothatanyvoltagefromthesensorwhenthevesselislevel
andnotmovingisacceptedbytheEK60asthe“normal”level”.
3RollVoltageSensitivity
Adjustthesensitivityfromthesensor.
4RollVoltageOffset
Adjusttheoffsetlevelsothatanyvoltagefromthesensorwhenthevesselislevel
andnotmovingisacceptedbytheEK60asthe“normal”level”.
5PitchVoltageSensitivity
Adjustthesensitivityfromthesensor.
6PitchVoltageOffset
Adjusttheoffsetlevelsothatanyvoltagefromthesensorwhenthevesselislevel
andnotmovingisacceptedbytheEK60asthe“normal”level”.
Relatedtopics
•NormalOperationonpage76
•Motiononpage107
164692/D