Technical information

Operationalprocedures
4Setminimumandmaximumdepthtothedesiredvalues.
5ClickOk.
Relatedtopics
Depthviewonpage55
BottomDetectiononpage140
Investigatinglowpingrate
ThisproceduresuggestsafewchecksyoucanmakeiftheEK60isunabletomeetyour
requiredpinginterval.
InsomecasesyoumayforexampleseearelevantmessageCannotmeetping
intervalrequirementthatindicatesthattheEK60failstopingasfastasyou
havespecied.
Thepingrateisnormallylimitedbythemaximumrangesettings.
Itwillalsobedependantonhardwareissues.Thismaybe,forexample,howfast
yourcomputercanhandletheinformationfromeachping,howfastyoursystem
communicateswithexternalperipherals,howlongtimethesystemusestosavedata,and
thetransceiverrechargingtime.
NumerousparametersettingsonyourEK60systemmayalsoaffectthepingrate.
Observethesestepstoinvestigate.
Procedure
1ChecktheMax.rangedisplayintheNumericalview.
Thisvaluesshowsthemaximumdatacollectionrangeresultingfromallsettings
madeintheEK60.Ifthevalueisvalueishigherthanyoumayexpect,observe
theremainingstepstolocatethecause.
Numericalviewonpage61
2CheckyourcurrentdisplayrangesetbytheSurfaceRangeandBottomRange
parametersforallviews.
Ifyouoperateinshallowwaters,butstillhasalargedepthrangeapplied,thiscan
reducethemaximumpingrate.
SurfaceRangeonpage151
BottomRangeonpage149
3Checkthebottomdetectionparametersforallchannels.
Ifthebottomdetectionrangesaresettoahighervaluethannecessary,thiscan
reducethemaximumpingrate.
BottomDetectiononpage140
164692/D