Simrad ES120-7CD Installation manual This document provides a general description of how to install the Simrad ES120-7CD Split-beam transducer. The information must be regarded as general guidelines and recommendations only. The installation shipyard must design and manufacture installation hardware to fit the ES120-7CD transducer on each individual towed body.
Document history Simrad document number: 339149 / ISBN: 978-82-8066-110-4 / Current revision: A Rev.A 02.10.2009 First version. Copyright ©2009 Kongsberg Maritime AS The information contained in this document remains the sole property of Kongsberg Maritime AS. No part of this document may be copied or reproduced in any form or by any means, and the information contained within it is not to be communicated to a third party, without the prior written consent of Kongsberg Maritime AS.
Installation manual Table of contents ABOUT THIS MANUAL ....................................................... 5 SIMRAD ES120-7CD .......................................................... 6 TOWED BODY DESIGN ...................................................... 7 HOW TO INSTALL THE TRANSDUCER ................................ 9 Examples ..................................................................................................................9 Example 1: Small transducer ..........................
Simrad ES120-7CD 4 339149/A
About this manual ABOUT THIS MANUAL Purpose The purpose of this installation manual is to provide generic descriptions and illustrations allowing the reader to understand the basic principles for echo sounder transducer installation. About the information provided in this document The information in this document must be regarded as general guidelines and recommendations only. The installation shipyard must design and manufacture installation hardware to fit each individual transducer and vessel.
Simrad ES120-7CD SIMRAD ES120-7CD The purpose of this manual is the provide the basic information required to install the Simrad ES120-7CD Split-beam transducer.
Towed body design TOWED BODY DESIGN A towed body used to hold the transducer is not provided by Simrad. The design and manufacturing of such a body must be made by your own organisation, or by a third party you wish to engage to do this. During the design phase, the following considerations must be made.
Simrad ES120-7CD the sound energy, and may in worst cases block the sound transmission totally. Therefore, design the towed body so that it can operate in deep water. Caution Observe the maximum operational depth of the transducer. Do not exceed this limitation. Do not allow the towed body to hit the sea bed. This may inflict permanent damage to the transducer(s).
How to install the transducer HOW TO INSTALL THE TRANSDUCER Installation on a towed body Transducers designed to withstand large water pressure are provided for use in towed bodies. The recommended installation method is through the hull plating hull using mounting and clamping rings. The installation arrangement on the towed body must be designed by the manufacturer of the towed body to fit its shape and characteristics.
Simrad ES120-7CD Example 1: Small transducer The illustration below shows the installation principle of a small circular transducer using clamping and mounting rings.
How to install the transducer Example 2: Medium and large transducers The illustration below shows the installation principle of a medium or large transducers. Note that a clamping ring is not required, as the transducer body is shaped to facilitate this function.
Simrad ES120-7CD Example 3: Dual transducer arrangement The illustration below shows a typical through the hull installation of small and large circular transducers on a towed body.
Transducer handling and maintenance TRANSDUCER HANDLING AND MAINTENANCE You MUST observe the following rules for handling, maintenance and painting. Rules for transducer handling Note Do not lift the transducer by the cable. Do not expose the transducer to direct sunlight. Do not expose the transducer to excessive heat. Transport protection Some transducers are delivered with a cover plate on the face for protection during transport.
Simrad ES120-7CD Approved anti-fouling paints This is Simrad’s list of approved antifouling paints on polyurethane transducer housing. Jotun Head office address: P.O.Box 2021, N-3248 Sandefjord, Norway Website: www.jotun.com. 1 Racing 2 Non-stop 3 Safeguard Universal primer (125 micron) with Antifouling SeaQuantum Ultra (125 micron) 4 Antifouling Seaguardian International Marine Coatings Address: World-wide offices Website: www.international-marine.com.
Transducer handling and maintenance Introduction to Emuge self-locking threads Emuge self-lock is a tap design with an integrated locking feature. Standard metric bolts are used. The internal thread provides a self-locking connection, which can be used repeatedly. It is not necessary to involve a secondary locking device (e.g. chemical, nylon or mechanical). The Emuge self-lock bolts withstand vibrations better than standard (metric) threads, because the thread contact stops the sideways movement.
Simrad ES120-7CD • Economically efficient locking system, no additional components are necessary • Undiminished holding power even under dynamic stress • Repeated loosening and re-tightening without loss of function • Internal threads can be produced with Emuge taps, cold forming taps or thread mills • Larger thread hole diameters, i.e.
Transducer handling and maintenance Figure 7 Example of use (CD017020C) Note In the case of tapping through holes it is important that the profile of the Emuge self-lock threads is in the correct direction compared with the entering direction of the bolt. Use Emuge self-lock gauges. Note that the gauge must be used in the correct direction. Self-lock taps provided by Simrad The following self-lock taps are on stock at Simrad, and can be ordered from us. Threads Drill diameter for threads Part.
Simrad ES120-7CD DRAWING FILE This chapter contains relevant drawings related to the electrical and physical installation of the Simrad ES120-7CD Split-beam transducer. Note The mechanical drawings are for information and guidance only. They are not in scale, and may differ slightly from the original drawings. All dimensions are in mm unless otherwise is noted. The original installation drawings are available on PDF and/or AutoCad format. Visit www.simrad.com to download.
Drawing file General Purpose Transceiver (GPT) wiring Observe the drawing below to connect the Simrad ES120-7CD Split-beam transducer to the General Purpose Transceiver (GPT). For more information about these connections, refer to the applicable echo sounder installation manual.
Simrad ES120-7CD General Purpose Transceiver (GPT) transducer plug assembly Upper plug case Plug fastening ring Contact body Retaining ring Outer screen and inner screen braid wire untaped and spread out under washer Outer screen together with inner screen. Drain wire, fold back over jacket and temporary fastened with tape. Heat-shrinkable tubing Lower plug case Washers Bottom cap and cable clamp Rubber sleeve Rubber sleeve Note: All measurements are in mm. The drawing is not in scale.
Drawing file Outline dimensions and installation drawings Note Observe the 32 Nm torque when the transducer is mounted using the mounting and clamping rings. Observe the 17 Nm maximum torque when the transducer is mounted using the threaded inserts on the transducer body .
Simrad ES120-7CD Outline dimensions [324407] Maximum tightening torque (M8): 17 Nm Nonstated radii: 2 mm Cable length: 1,5 m Weight in air: 4,5 kg Weight in water: 2,2 kg (76) M8, depth 12 mm ø130 ø152 (Bottom) R1 Guide cam FOR WARD R5 ø180 80 ø24 70,2 85,2 R1 All measurements are in mm The drawing is not in scale 22 324407 Rev .
Drawing file Mounting ring [204675] 339149/A 23
Simrad ES120-7CD 24 339149/A
Drawing file Clamping ring [204677] 339149/A 25
Simrad ES120-7CD 26 339149/A
Index Index A About, 5 information in this manual, 5 Additional information, 5 Air bubbles, 7 Anti-fouling paint, 14 Approval maritime authorities, 5 C Clamping ring blister, 9 drawing, 25 example, 10 D Depth, 7 Dimensions drawing, 22 Drawing Clamping ring, 25 GPT Transducer plug, 20 Mounting ring, 23 outline dimensions, 22 Drawing file, 18 E Emuge, 15 Example Clamping ring, 10 Mounting ring, 10 G GPT Transducer plug drawing, 20 H Handling, 13 Handling rules, 13 Heat, excessive do NOT expose, 13 I In
Simrad document number: 339149 ISBN-13: 978-82-8066-110-4 ©2009 Kongsberg Maritime AS S im r a d Ko n g s b e r g M a r it im e A S S t ra n d p rom e n a d e n 5 0 P. O. Bo x 1 1 1 N- 3 1 9 1 H o r t e n , N o r w a y Te le p h o n e : + 4 7 3 3 0 3 4 0 0 0 Te le fa x : + 4 7 3 3 0 4 2 9 8 7 w w w . s im r a d . c o m c o n t a c t @ s im r a d .