Installation manual

Drawingle
ø35
ø65
Stuffingtube
Washer
Rubbergasket
Washer
Packingnipple
Serviceloop
oncable
Minimum
400mm
Steelconduit
Air/wateroutlet
(optional)near
theechosounder ,
abovewaterlevel
Recommendedtransducerlocation
Approx3deg
Approx1m
Minimum
400mm
Important:
Anti-foulingpaint:
Steelconduit:
Lifting:
Incaseofslamminginroughsea,
usesupportbeam099-206575.
Thetransducerfaceismadeof
polyurethane.Ingeneral,duetothe
riskofchemicalreaction,itmustnot
painted.Iffoulingisaproblem,
observetherecommended
antifoulingpaintslistedinthe
transducerinstallationmanualand
onwww.simrad.com.
Recommendedtominimize
electricalinterference.
Minimuminsidediameter:35mm
Wallthickness:6mm(or4.5mmif
galvanizedconduitisused)
DONOT liftthetransducerbyits
cable.
Allmeasurementsinmm.
Thedrawingisnotinscale
820-074544Rev .F
CD017022-01 1Page2of2
130003/D