Installation manual

Drawingle
Supportbar[206574]
1)Useadrill,orsimilartool,toopentheboltholesinthetransducerflange. Theholesarepartlyfilled
upwithpolyurethanemouldingcompound. Thiscompoundiseasilyremovedwithasharptool.
2)Mountthetransducercableasshownondrawing820-074544.
3)Mountthesupportbarinsidethemountingringasshown.
4)Heaveupthetransducer,andfastenittothemountingringasshownomdrawing820-074544.
5) Tightenthescrewsattachedtothesupportbar.Useakey8mmhexagonsocketwrenchthroughthe
holesinthetransducerflange.Donotscrewtootight,maximumtorqueis0.5NM.
6)Fillthecavitiesaroundtheboltheads,andinthetransducerflange,bymeansofasyringe
containinganelasticandremovablecompund."Sicaflex"orsimilarisrecommended.
Itisimporanttosecurethebolts!
Elasticcompound
Mounting
ring
(499-074076)
Socketheadcapscrew
Class80
M10x120
A4-80-MC6S
(560-078780)
Supportbar(*)
(579-206572)
(*)Onthe Autocaddrawing,thisitemis
referredtoas"SupportingChannel"
Clamp
(579-206570)
Clamp
(579-206570)
Transducerbody
A
A
A - A
Allmeasurementsinmm.
Thedrawingisnotinscale
820-206574Rev .A
CD017029-001Page1of2
130003/D