Installation manual

SimradES70
Procedure
1ClicktheActiveicon.
ThisiconislocatedundertheMainmenu.ItisusedtoopentheActive
menu.
Activemenuonpage112
2ClickEchogramtoopentheEchogramdialog.
TheEchogramdialogallowsyoutosetuptheparameterscontrollingtheechogram
presentation.Thethreetabscontrolthehorizontallines,theechogramtypewith
appliedTVG,andhowfasttheechogrammovesacrossthedisplay.
3OntheLinestab,observethevariouslinesthatcanbeapplied.
4ClickBottomLinetoenableview.
5ClickeitherWhitelineorHardnesstoselectwhichlinetoshow.
6ClickOKtosavethecurrentsettingsandclosethedialog.
Rangeprocedures
Theseproceduresexplainhowtochangetheverticalrange,thatishowtocontrolthe
depthtobeshownbytheechogram.
Topics
Choosingstartdepthonpage60
Choosingautomaticstartdepthonpage61
Choosingtheverticalrangeonpage62
Choosingstartdepth
Thisprocedureexplainshowtocontroltheverticalstart
range(startdepth)intheechogram.Thestartrangeis
controlledbytheStartRangebuttonontheMainmenu.
Example6StartRangeinasurfacerelatedechogram
Inasurfaceechogram,settheStartRangevalueto0meters.Thiswillmakethe
echogramstartfromtheseasurface(providedthatthetransduceroffsethasbeen
dened).SetRangetothecurrentdepthplus20meters.Theechogramwillnow
showtheareafromtheseasurfaceanddownto20meters“below”thebottom.
Thebottomcontouriseasilydetectedwhenthedepthchanges.
Threedifferentmethodsmaybeused.