Simrad Marine Computer Installation manual This manual provides you with the basic information required to install the Simrad ES70/PI50 Marine Computer. The Marine Computer is provided as an option for the Simrad ES70 Echo Sounder System, and the Simrad PI50 Catch Monitoring System.
Document history Document number: 345266 / Rev. A / ISBN: 978-82-8066-123-4 Rev.A 11.03.2010 First version. Copyright ©2010 Kongsberg Maritime AS The information contained in this document remains the sole property of Kongsberg Maritime AS. No part of this document may be copied or reproduced in any form or by any means, and the information contained within it is not to be communicated to a third party, without the prior written consent of Kongsberg Maritime AS.
Installation manual Table of contents ABOUT THIS MANUAL ....................................................... 5 INSTALLATION PROCEDURE ............................................. 6 Physical installation..................................................................................................7 Display setup ............................................................................................................8 Single display ..................................................................
Simrad ES70/PI50 Marine Computer Cables........................................................................................................ 32 Internal batteries ......................................................................................... 33 Dehumidifier .............................................................................................. 33 Coatings..................................................................................................... 33 Re-packaging...............
About this manual About this manual Purpose The purpose of this manual is to provide the information and basic drawings required for installation of the Simrad Marine Computer. For more detailed information about the practical use of the host product, refer to the relevant echo sounder or catch monitoring system documentation. Installation drawings Detailed vessel specific mechanical drawings for the installation must be provided by the customer, or any shipyard contracted to perform the installation.
Simrad ES70/PI50 Marine Computer Installation procedure This chapter describes how to do the physical installation of the computer and the power supply, as well as the display setup.
Installation procedure Physical installation The ES70/PI50 Marine Computer is an industrial computer. It is small, rugged, and contains no moving parts. This means that fans, hard disks and CD drives are omitted. The computer provides Ethernet sockets, RS-232 serial lines, and a number of USB connectors. The hard disk is replaced with a solid state drive (SSD). The Marine Computer is easily mounted with the brackets supplied with the unit.
Simrad ES70/PI50 Marine Computer Display setup Topics • Single display on page 8 • Dual display on page 9 Single display The ES70/PI50 Marine Computer is provided with Windows 7® operating system, and all operational software installed. This includes the display setup. However, the computer will automatically sense the display you connect during system installation, and which video output you use. Depending on these choices, you may need to set up the display resolution to fit your requirements.
Installation procedure Figure 2 Screen Resolution dialog with default parameters shown 4 Set Multiple displays to Show desktop only on 2, then click Apply. 5 Observe message dialog: Do you want to keep these display settings? 6 Click Keep change. 7 Set Resolution to 1280 x 1024, then click Apply. 8 Observe message dialog: Do you want to keep these display settings? 9 Click Keep change. 10 Click OK to save the current settings and close the dialog.
Simrad ES70/PI50 Marine Computer 1 Place the cursor on the computer desktop, and right-click to open the short-cut menu. 2 Select Screen Resolution on the menu. 3 Observe the default configuration: • Displays: 1|2 Multiple Monitors • Resolution: 1024 x 768 • Orientation: Landscape • Multiple displays: Duplicate these displays Figure 3 4 Screen Resolution dialog with default parameters shown At the top of the Screen Resolution dialog, observe that two display icons are shown; [1|2] and [3].
Software procedures Software procedures This chapter provides procedures for software installation, backup restore, and activation of the operating system.
Simrad ES70/PI50 Marine Computer Software installation, upgrade and removal If the ES70/PI50 system is provided with a computer, it is delivered with all necessary software installed, configured and tested. If you use your own computer, you must do this yourself. Software upgrades are useful if your ES70/PI50 fails, and you suspect a software error. An upgrade is also required whenever the ES70/PI50 software is modified.
Software procedures 7 Observe the start-up procedure in the Getting started chapter. This chapter is provided in the ES70/PI50 Operator manual and ES70/PI50 Reference manual. How to obtain the ES70/PI50 license The ES70/PI50 requires a valid license to operate. Without a license you will not be able to communicate with the transceiver. The ES70/PI50 requires a valid license to operate. Without a license you will not be able to communicate with the Receiver Unit.
Simrad ES70/PI50 Marine Computer How to upgrade the ES70/PI50 software Use this procedure if you wish to reinstall the software, or receive a new CD-ROM with a software upgrade. 1 Observe the procedure for software installation. → How to install the ES70/PI50 software on page 12 Unless you have made any hardware changes on your computer, the existing software license will be used. How to remove the ES70/PI50 software 1 Observe the operating system’s functionality for software removal.
Software procedures 11 Observe that the computer restarts automatically. 12 After approximately four minutes, observe the following message: Type your windows product key 13 Enter the license key. The license key is located on a small sticker under the computer chassis. 14 Make sure that Automatically activate windows when I‘m on-line is selected. 15 Click Next. 16 Observe that the restore finishes automatically. Note The Windows license must be activated within 30 days.
Simrad ES70/PI50 Marine Computer Windows 7 activation Once the Windows 7® operating system has been installed, either from scratch, or from a restore disk or USB memory stick, it must be activated. You must activate Windows within 30 days of installation. Activation helps verify that Windows on your computer is genuine and that it hasn’t been used on more computers than the Microsoft Software License Terms allow. In this way, activation helps prevent software counterfeiting.
Software procedures 5 If your computer is connected to the Internet, click Activate Windows online now. This process is automatic. Sit back and wait, and follow the instructions provided. 6 If your computer is not connected to the Internet, click Show me other ways to activate. 7 In the next dialog, click Use the automated phone system. Figure 6 8 Locate your country on the list, then click Next.
Simrad ES70/PI50 Marine Computer Cable layout For information about the cabling of the entire system, refer to the applicable installation manual.
Cable layout Rear panel connectors Figure 9 Marine Computer, rear connectors A Switch for remote on/off control of external devices. The internal switch is closed when the computer is powered up. B DC input from power supply (12 to 30 Vdc) Note Supply voltage ground is also computer chassis ground. C Top: Audio output (use stereo mini-jack plug) Bottom: Microphone input (use stereo or mono mini-jack plug) D DVI output to display E Serial inputs and outputs. Use the adapter cable included.
Simrad ES70/PI50 Marine Computer Connector wiring This section only holds the cable drawings directly related to the Marine Computer. For the remaining cable drawings for the PI50 or ES70 system, refer to the applicable installation manual.
Cable layout Generic RS-232 Serial line This cable holds a multi purpose serial line. It provides interface with any peripheral unit. One end of the cable connects to the local unit (DTE) with a 9-pin D-connector, while the other connects to the peripheral (DCE) as described in the peripheral unit’s documentation. Note that this cable does not support all the signals in the standard RS-232 specification. Cable specifications • Conductors: 3 x 0.
Simrad ES70/PI50 Marine Computer Generic RS-422 Serial line This cable holds a multi purpose RS-422 balanced serial line. It provides interface with any peripheral unit. One end of the cable connects to the local unit (DTE) with a 9-pin D-connector, while the other connects to the peripheral (DCE) as described in the peripheral unit’s documentation.
Cable layout Serial line adapter This is a commercial adapter. It allows you to connect four RS-232 serial lines to a common socket on the computer. Female 9-pin D-connectors identified as "A" through "D" To socket on computer W510 Rev.
Simrad ES70/PI50 Marine Computer Drawing file This chapter contains the installation and outline dimension drawings for the Simrad Marine Computer. Note The mechanical drawings are for information and guidance only. They are not in scale. All dimensions are in mm unless otherwise is noted. The original installation drawings are available on PDF and/or AutoCad’s DWG format. Visit www.simrad.com to download.
Drawing file Marine computer outline dimensions 80 86 268 86 264 80 219 207 195 184 224 Note: All measurements are in mm. The drawing is not in scale. 345266/A CD010218A Page 1 of 1 Rev.
Simrad ES70/PI50 Marine Computer APPENDIX A — GENERAL SAFETY RULES The Simrad ES70/PI50 Marine computer system operates on 230 Vac 50/60 Hz. WARNING This voltage is lethal! The following safety precautions must be followed at all times during installation and maintenance work • Always switch off all power before installation or maintenance. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is being carried out on the system.
Appendix B Equipment handling APPENDIX B — EQUIPMENT HANDLING This section provides the basic rules for transportation, storage and handling of units. In this context, a unit may be any large or small part of the system. It can be supplied as part of the initial delivery, or as a spare part.
Simrad ES70/PI50 Marine Computer Ensure that all available lifting lugs are used. Ensure the unit remains under control during the operation to avoid damage to the unit, equipment or personnel. Heavy units may be transported using a forklift truck. Special attention must then be paid to the position of the unit’s centre of gravity. The units must be properly secured to the truck.
Appendix B Equipment handling 13 If the unit contains normal batteries, these may have been disconnected/isolated before the unit was packed. These must only be reconnected before the installation starts. Units containing batteries are marked. Caution Units containing lithium or alkaline batteries must be handled separately and with care. Such units are marked accordingly. Do not attempt to recharge such batteries, open them or dispose of them by incineration. Refer to the applicable product data sheets.
Simrad ES70/PI50 Marine Computer 1 Check the carton before opening it to ensure it shows no signs of dropping, immersion in water or other mishandling. If the carton shows signs of such damage, refer to the paragraph covering Inspection on receipt. 2 Place the carton on a stable work bench or on the floor with the top of the carton uppermost. 3 In the absence of other instructions, always open the top of the carton first.
Appendix B Equipment handling Unpacking transducers Transducers may be supplied mounted to a hull unit (if any), or packed separately. Crates are normally identified by the order number and the serial number. The transducer face must be protected by a rigid, padded cover (e.g. a wooden box lined with foam rubber) all the time it is exposed to the risk of physical damage.
Simrad ES70/PI50 Marine Computer Cleaning cabinets If a cabinet has been exposed to salt atmosphere while it was in use, it must be thoroughly cleaned both internally and externally to prevent corrosion. 1 Wipe the cabinet externally using a damp cloth and a little detergent. Do not use excessive amounts of water as the unit may not be water tight. On completion, dry the unit thoroughly. 2 All surfaces must be inspected for signs of corrosion, flaking/bubbling paint, stains etc.
Appendix B Equipment handling Internal batteries If the unit contains batteries, these may discharge slowly during storage. If the unit is to be stored for an extended period, disconnect or remove all internal batteries. A suitable piece of insulating material can be placed between the battery and the electrical contacts to prevent electrical discharge. The battery can then remain in the unit, reducing the risk of it being misplaced during the storage period.
Simrad ES70/PI50 Marine Computer Must not be transported or stored in temperatures below -5 degrees Celsius. Other units can normally be stored in temperatures between -30° C and +70° C, refer to the system’s technical specifications for details. Unless otherwise specified, transducers must not be stored in temperatures below -20° C and above +60° C. Circuit board handling and packaging Circuit boards are delicate items.
Appendix B Equipment handling Unpacking on board the vessel When you are working on board a vessel, an “approved conductive service mat” is often far away. As you still need to unpack circuit boards, make sure that you do it in the instrument room, or at another location where you have a steel deck. Keep far away from the bridge or any other rooms with wall-to-wall carpets! If possible, bring a wristband and ground yourself.
Simrad ES70/PI50 Marine Computer 2 The service personnel involved must wear a wristband in direct contact with the skin, connected to the service mat. 3 Printed circuit boards must be placed on the conductive service mat during installation, maintenance etc. 4 If, for any reason, it is necessary to move the circuit board from the conductive service mat, it must be placed in an approved antistatic transportation container (e.g. static shielding bag) before transportation.
Appendix C Basic cable requirements APPENDIX C — BASIC CABLE REQUIREMENTS This chapter provides general information related to the installation of system cables.
Simrad ES70/PI50 Marine Computer • To allow for future expansion of the system, all cables should be allocated spare conductor pairs. Also, space within the vessel should be set aside for the installation of extra cables.
Appendix C Basic cable requirements and designed to ensure a good ground connection. The glands used must be firmly attached to, and in good electrical contact with, a metal structure grounded in accordance with these recommendations. Electrical continuity must be ensured along the entire length of all cable coverings, particularly at joints and splices. In no case should the shielding of cables be used as the only means of grounding cables or units.
ISBN: 978-82-8066-123-4 ©2010 Kongsberg Maritime AS