Installation manual

SimradPI50
Receipt,unpackingandstorage
Uponacceptingshipmentoftheequipment,theshipyardand/orthedealershouldensure
thatthedeliveryiscompleteandinspecteachshippingcontainerforevidenceofphysical
damage.Ifthisinspectionrevealsanyindicationofcrushing,dropping,immersionin
wateroranyotherformofdamage,therecipientshouldrequestthatarepresentative
fromthecompanyusedtotransporttheequipmentbepresentduringunpacking.
Allequipmentshouldbeinspectedforphysicaldamage,i.e.brokencontrolsand
indicators,dents,scratchesetc.duringunpacking.Ifanydamagetotheequipmentis
discovered,therecipientshouldnotifyboththetransportationcompanyandKongsberg
MaritimesothatKongsbergMaritimecanarrangeforreplacementorrepairofthe
damagedequipment.
Onceunpacked,theequipmentmustbestoredinacontrolledenvironmentwithan
atmospherefreeofcorrosiveagents,excessivehumidityortemperatureextremes.The
equipmentmustbecoveredtoprotectitfromdustandotherformsofcontamination
whenstored.
Formoreinformation,seetheappendixrelatedtoequipmenthandling.
Equipmenthandlingonpage116
Generalinstallationrequirements
ThefollowinginstallationrequirementsareapplicabletothisKongsbergMaritime
delivery.
Approvalbyclassicationsociety
TheSimradPI50hydrophoneinstallationmustbeapprovedbyDetNorskeV eritas
(DNV)oranotherclassicationsociety.Theshipownerandshipyardperformingthe
installationareresponsibleforobtaininginstallationapproval.
Supplypower
Thesupplyvoltagetotheequipmentistobekeptwithin±10%oftheinstallation’s
nominalvoltage.Maximumtransientvoltagevariationsonthemainswitchboard’s
bus-barsarenottoexceed-15%to+20%ofthenominalvoltage(exceptunderfault
conditions).
Compassdeviation
Oncetheinstallationiscomplete,thevesselmustbeswungwiththesysteminboth
theoperativeandinoperativemodes.Theshipownerandcaptainareresponsiblefor
updatingthedeviationtableaccordinglywithregardtothevessel’snationalregistryand
correspondingmaritimeauthority.