Installation Instructions

18
|
Connecting power | NSS Installation Manual
Connecting power
Power connection (basic)
The NSS display can be powered by either 12 V
or 24 V DC. Displays are protected against reverse
polarity, under voltage and over voltage.
The supplied power cable has a four core cable
used for:
power into the system (Red and Black wires)
controlling power state of the display or power
state of other displays and devices (Yellow wire)
connecting to an external alarm (Blue wire)
Connect red to (+) DC using a 5 amp fuse for NSS12, and a 3 amp fuse for NSS7 and NSS8.
Connect Black to (-) DC. The display can be powered on and o using the power button.
Power Control (yellow wire)
Planning is required how you want to be able to turn on and o the NSS an connected com-
patible devices.
The yellow (Power Control) wire on the NSS power cable can either be an input that will turn
on the display when power is applied, or an output that turns on other devices when the
display is powered on. It can be con gured at the installation stage to control the power state
of displays and compatible devices. When commissioning the system, displays can be set to
be a Power Control Slave or Power Control Master.
Power Control con guration options of the NSS are:-
use the Power button to turn on the display only: Yellow wire not connected
display to turn on when power is applied to the display: Common red and yellow wires
use the Power button to turn on the display and other displays and or compatible devices
such as Broadband Radar: Yellow wire connected to a Power Control Bus. (Set one or more
displays to be a Power Control Master)
12 - 24 V DC
Red (FUSE)
Black
Yellow
No Connect
+
_
Blue
12 - 24 V DC
Red (FUSE)
Black
Yellow
Blue
+
_
No Power Control
Yellow Wire: No Connect:
Display will turn on and o when the
power button on the front of the unit is
pressed. Power Control wire is not attached.
Auto Power on
Display will turn on when power is applied
to the display. Common the yellow wire with
the red wire after the fuse.
Note: The unit can not be powered down
but can enter a standby mode. (screen back-
light o ).
4
12 - 24 V DC
Red (FUSE)
Black
Yellow
No Connect
+
_
Blue