Using the SG05 EVC gateway
The SG05 is connected to the SimNet network in place of Autopilot computer. It connects to
a Volvo Gateway for communication with Volvos EVC system.
Note that rudder angle data is sourced from the EVC system and a seperate rudder angle
indicator is not required.
12 V DC
-
+
T
T
T
SimNet drop cable
SimNet Backbone
SimNet terminator
1
2
3
5
4
6
1 NSS Display
2 Simrad SGO5 SimNet - Volvo Gateway
3 Volvo Gateway (p/n: 000-1-258-001)
4 12V DC Supply
5 SimNet 7 way connector
6 RC42 Rate Compass
Autopilot setup
Verifying the autopilot connection
When an AC12, AC42, or SG05 is connected to the NSS system, the NSS will automatically
detect the autopilot and an Autopilot menu item will be included in the Settings menu.
If no
Autopilot item is available in the menu, establish the connection by running the auto
select process.
The auto select process may also be used if the list of data sources needs to be updated when
a unit has been physically replaced.
If the AC12, AC42 or SG05 is later disconnected, the
Autopilot menu item will remain avail-
able, but only a few of the menu items will be available.
Commissioning the autopilot
When the autopilot installation is completed, the commissioning procedures must be per-
formed. Failure in setting up the autopilot correctly may prohibit the autopilot from function-
ing properly.
The setup of the autopilot computers (AC12/42) can be done in full from either an NSS unit or
from an AP24 or AP28 control head (if  tted). The following sections describe how you con-
gure the autopilot from the NSS unit. If you select to setup the system from an AP24 or AP28