Operation Manual

Table Of Contents
Installation
22081814H 101
Abbreviated
name
Description / Usage NOTES
RFC For use when selecting between
Robertson fluxgate compasses
RFC : J300X, RFC35 compass
connected to junction unit
RFC : RFC300, RFC300 compass
connected to ROBNET
MAGN For use with magnetic compass
(APC100) with course detector
(CD100)
MAGN : J300X, CDI35 + CD100
connected to junction unit.
MAGN : CI300X, CD100 connected
to CI300X
FLUXG For use with non-Robertson
fluxgate compasses that output
SIN/COS
Optional CI300X item. Only
available if WIND has not been set
to CI300X
GYRO For use with Robertson RGC50,
RGC10 gyro
Optional CI300X item. True data
displayed for HDG, COG, bearing
to waypoint
Output
INSTR
For high speed NMEA output
of compass heading
HDM or HDT output increased
from 1 to 5 times/sec. on TX1 port
Output
RADAR
Clock/data heading output to
radars
Selectable between Anritzu and
Furuno. (On both J300X and
NI300X)
The Interface Setup Menu presents these names so that they can be
assigned to a hardware input or output port. Each abbreviated name is
then presented in appropriate locations of the USER SETUP MENU to
provide the user with choices of data sources, or identified to the
AP300X where to look for various types of data.
When you assign a hardware port to an abbreviated name, you are
simply telling the AP300X system that when the user chooses an
abbreviated name as a data source it should look to the hardware port
assigned to the abbreviated name for the data.
It is recommended that upon completion of the ISM that the
configuration be recorded in the Interface Setup Table on page 100.
Enter the Interface Setup part of the ISM by pressing and holding
the NAV/ Setup button for five seconds.
Scroll through to the Interface setup ? prompt by pressing the
STBD [>]
The following display will be presented:
Setup?
Interface
INSTALLATION
To access the Interface Setup items, turn the course selector clockwise.
The display will show: