Operation Manual

Table Of Contents
Robertson AP300X Autopilot
92 22081814H
CD100 Course Detector
On some installations the owner may prefer to use the boats own
compass. The compass must be fully gimballed and have a flat surface
underneath to fit the CD100. Make hole for a 6 mm screw in the bottom
of the compass and mount the CD100 as shown on the drawing. Secure
the 6 mm screw through the centre hole of the CD100. Make sure the
cable does not prevent the compass from moving freely in the gimbals.
1 Screw M6x25mm, non
magnetic
2 Washer, non magnetic
3 Course detector
4 Cable clamp, nylon
5 Washer, non magnetic
6 Screw M3x10mm, non
magnetic
Note ! Lock nut on mounting screw (pos. 1)
for transportation only. To be removed
before mounting.
CDI35 Interface
Locate the CDI35 as close to the compass as possible so that there will
be no problem finding it in the event of a service.
Put the two fixing screws in the slots and secure the unit to the
bulkhead. Open the unit to access the screw terminals.
Cut the CD100 cable to make a suitable length and connect both cables
as shown on the diagram below.
* NON-POLARIZED
(COLOR INDEPENDENT)
JUNCTION UNIT
MAIN PCB
HS+
*
Heading
Sensor
HS
CDI35 INTERFACE PCB
BOAT'S
MAGNETIC
COMPASS
CD100
COURSE
DETECTOR
White
Brown
Green
Yellow
Grey
12
3
4
5
Note ! When CD100 Course Detector is mounted upside down, the yellow and gray
conductors must be interchanged
3
2
1
4
5
6