Operation Manual

Parameters
119
850-164385 / Rev.C
Pulse Form
The Pu lse Form is accessed from the Horizontal and Vertical
menus.
The Pu lse Form parameter dialogue is used to select the form of
the transmitter pulse. This could either be CW (Continuous Wave)
with different pulse lengths, or FM (Frequency Modulation) with
different pulse lengths and number of frequencies.
Range
(meters)
CW
Pulse length (ms)
AUTO
mode (ms)
FM
Pulse length(ms)
Short Normal Long Short Normal Long
50 0.4 0.8 1.2 FM 6.4 3.2 6.4 6.4
75 0.6 1.2 2.0 FM 6.4 3.2 6.4 6.4
100 0.8 1.5 2.5 FM 6.4 3.2 6.4 6.4
150 1.2 2.5 4.0 FM 6.4 3.2 6.4 6.4
200 1.5 3.0 5.0 FM 12.8 3.2 12.8 12.8
300 2.3 4.5 8.0 FM 12.8 3.2 12.8 12.8
400 3.0 6.0 10 FM 25.6 3.2 12.8 25.6
500 3.8 7.5 13 FM 25.6 3.2 12.8 25.6
600 4.5 9.0 15 FM 25.6 3.2 12.8 25.6
750 6.0 12.0 20 CW 20 3.2 12.8 25.6
1000 7.5 15.0 30 CW 30 3.2 12.8 25.6
1200 9.0 18.0 30 CW 30 3.2 12.8 25.6
1500 11.3 22.5 30 CW 30 3.2 12.8 25.6
2000 15.0 30.0 30 CW 30 3.2 12.8 25.6