Main switch
Main switch functions control power to the sonar, hoisting and
lowering of the transducer and indicates the transducer’s current
position.
Power
Pressing Power for approximately two seconds powers up the
sonar. The adjacent green LED blinks while the Sonar Control
Unit boots up, and remains illuminated once the system is
operational.
Before the sonar can be powered down, the transducer must be
in the Up position. Pressing the Power button for approximately
two seconds secures power to the unit which is confirmed by the
adjacent green LED being extinguished.
Up
Raises the transducer to its upper position. The adjacent green
LED blinks while the transducer is raised and remains
illuminated once it is housed safely inside the hull of the vessel.
The green blinking LED will also be accompanied by an audible
signal.
Middle
Raises or lowers the transducer to its middle position.
The physical location of the middle position can be defined in
the Tr ansducer parameter dialogue.
Down
Lowers the transducer to its lower position. The adjacent green
LED blinks while the transducer is lowered and remains
illuminated when lower position is reached. The green blinking
LED will also be accompanied by an audible signal.
Related topics
Transducer, page 141