Installation Guide

7. If the concrete is not level, washers may be placed over anchor bolts and before shoes are bolted down to serve as
leveling devices.
8. Position the skirt covers over the shoes, covering the metal plates. Skirts must be inserted prior to posts being attached.
9. Attach the mounting brackets to the posts with fasteners in pre-drilled holes. For line posts, the upright straps will be
inserted into the channels of the post on the outside of the plastic, but for end posts, corner posts, and gate posts the
upright straps are inserted inside the steel in the center of the post. Each side of the strap gets three staggered screws
installed from opposite sides of the post for line posts and three each for ends and corners.
10. With the rst shoe anchored, and the post attached, determine and mark the next shoe position using a panel stiffener
as a spacer. It will measure 71.5” (for 3’ high and 6’ high) from the center of the next post and 1” shorter for a line to
a corner post. For 4’ high and 8’ high sections, it will measure 96” center to center.
11. Cut 7/8” of the bottom panel stiffer to accommodate the shoe strap and its screws. It is also recommended to remove
½” off the lower two feet on both sides of the panel edge to accommodate the shoe straps as well.
12. Mark and drill the holes for the next shoe.
13. Once all the shoes and posts are securely anchored to the wall and skirts are in place, insert the panels. Be certain that
steel stiffeners are in both top and bottom rails of each panel.
14. Finally, place the caps on the post for a nished look.
Concrete Surface Mounting Brackets
Need Help? Call us at 1.866.648.9336
Retaining Wall
SimTek can be installed on top of an 8" min width poured concrete
wall or on flat concrete by using concrete mounting brackets
5
"
6.5
"
.75
"
4.25
"
1.5
"
3.5
"
.75
"
1.5"
24
"
End Shoe
10"
6"
End Shoe Skirt
Corner Shoe Skirt
Line Shoe Skirt
5
"
8
"
.75
"
6.5
"
.75
"
3.5
"
1
"
24
"
Line Shoe
10"
6"
9"
9"
8
"
Minimum Bolt
size 1/2" x 4.5"
5.5
"
.75
"
5.5
"
.75
"
7
"
7
"
1.25
"
24
"
Corner Shoe
5
"
6.5
"
8
"
3.5
"
.75
"
.75
"
2.5
"
24
"
23
"
2
"
Gate Shoe
Use epoxy anchors
instead of wedge
anchors for gate shoe
10"
6"
Gate Shoe Skirt
6' Concrete Mount Specifications
U.S. Patents: 7,478,797 / 7,635,114 Foreign Patents Pending
Date: Jun 24, 2014
Sheet 1 of 1
TM
Scale: not to scale
REV: D Barlocker
This drawing may not be altered or reproduced without the
permission of SimTek Fence
Surface Mount Specs
www.simtekfence.com
Retaining Wall
SimTek can be installed on top of an 8" min width poured concrete
wall or on flat concrete by using concrete mounting brackets
5
"
6.5
"
.75
"
4.25
"
1.5
"
3.5
"
.75
"
1.5"
24
"
End Shoe
10"
6"
End Shoe Skirt
Corner Shoe Skirt
Line Shoe Skirt
5
"
8
"
.75
"
6.5
"
.75
"
3.5
"
1
"
24
"
Line Shoe
10"
6"
9"
9"
8
"
Minimum Bolt
size 1/2" x 4.5"
5.5
"
.75
"
5.5
"
.75
"
7
"
7
"
1.25
"
24
"
Corner Shoe
5
"
6.5
"
8
"
3.5
"
.75
"
.75
"
2.5
"
24
"
23
"
2
"
Gate Shoe
Use epoxy anchors
instead of wedge
anchors for gate shoe
10"
6"
Gate Shoe Skirt
6' Concrete Mount Specifications
U.S. Patents: 7,478,797 / 7,635,114 Foreign Patents Pending
Date: Jun 24, 2014
Sheet 1 of 1
TM
Scale: not to scale
REV: D Barlocker
This drawing may not be altered or reproduced without the
permission of SimTek Fence
Surface Mount Specs
www.simtekfence.com