User manual

sinaCAM Installation
User Manual Rev.: E 15
7.4 Calculation of Maximum Cable Length
The maximum cable length between remote camera heads and base unit is limited by the signal
attenuation and the conductor DC resistance of the used cable type.
Maximum cable length as limited by signal attenuation (rule of thumb):
Max. cable length = 25 dB / attenuation at 1.5 GHz
Maximum cable length as limited by conductor DC resistance (rule of thumb):
Max. cable length = 8 Ω / conductor DC resistance
Example calculation for Belden 1505F Flexible cable:
Nom. attenuation at 1.5 GHz: 13.300 dB / 100 ft
Nom. conductor DC resistance: 12.2 Ω / 1000 ft
Max. cable length = 25 dB / (13.300 dB /100 ft) = ~188 ft (57 m)
Max. cable length = 8 Ω / (12.2 Ω / 1000 ft) = ~656 ft (200 m)
The lower of the two values determines the approximate maximum cable length, in this example 188 ft
(57 m).
7.5 Connecting the Hardware
Make sure that all hardware to be installed is switched off.
Connect all hardware to the base unit.
Switch on all hardware and the base unit.