7.9 Installing Lenses
Attach C-mount lenses, suitable for 2/3 CCD cameras, to the standard C-mount thread of the remote
heads.
In case of B4-mount or PL-mount lenses use the corresponding adapters (option).
7.10 Adjusting the Lens Scale Position
Depending on filming situations, it can be necessary to equip a lens at a different angle than usual for the
lens scale to remain readable. For this, sinaCAM remote camera heads support 12 different positions for
the lens mount, each 30° apart. The lens mount is held in the chosen position by the lens mount lock, with
the lens scale on top by default.
Figure 13:
Adjusting the Lens Scale Position
To adjust the lens scale position follow these steps:
Remove the screw from the lens mount locks lower screw hole, then partially screw it into the upper
one (1).
Note: The screw will not go all the way in.
Grip the screw head to pull out the lens mount lock (2).
Make sure the locking lever is in the open position (3).
You can now adjust the position of the lens (4).
Note: Inside, the lens mount is equipped with 12 holes (each 30° apart) for
the lens mount lock.
Choose one of the valid positions, then reinsert the lens mount lock (5) to fix
the lens mount in its place.
Move the screw back into the lower screw hole of the lens mount lock and
tighten it (6).
Then move the locking lever back into the closed position (7).