User manual
The Menus sinaCAM
36 Rev.: E User Manual
Figure 27:
GenLock Example Setup with two sinaCAM Base Units and their Settings
9.4.3.1 FreeRun (Free Run)
The camera doesn’t synchronize with any signal. Even if it should receive sync data, it will run on its own
clock completely free from any synchronization.
9.4.3.2 Slv+Term (Slave+Terminating)
The camera is last in a synchronization chain and terminates the signal.
9.4.3.3 SlvChain (Slave Chain)
The camera is in the middle of a synchronization chain. It syncs itself to the signal and forwards the sync
signal to subsequent devices.
9.4.3.4 ExpTrgIn (Exposure Trigger In)
The Exposure Trigger In option enables providing an external trigger signal via the camera’s AUX
terminal. "Falling edge" triggers exposure of the sensor while "rising edge" triggers the reading of sensor
data.
Note: The Shutter setting is ignored when this GenLock mode is active. The HD-SDI output is not in
sync with the exposure trigger signal!