3 Select the [Extruder] menu.
󱈾 Wait until the nozzle’s temperature reaches the target temperature.
󱈾 Operate the extruder to insert the filament by 50 mm.
(If the filament was not injected, repeat step 2 for two to three times. If this does not work, please contact our
customer service hotline, and submit a video or image of this issue to a customer service representative.)
Note
-
When the filament is normally extruded (when notification 601 occurs)
󱇱
Remove the snap ring from the nozzle and remove the tube.
󱇱
Insert the encoder cleaning brush into the tube holder and move it up and down about 10 times to clean it.
󱇱
After cleaning, insert the tube again and assemble the snap ring.
For details on how to remove and assemble the snap ring and tube, refer to “1.5 Cleaning the Inside of the
Nozzle” in Chapter 5 of the User Manual.
Encoder Cleaning Brush
Tube Holder