User's Manual
UI Menu Function
2-8
2
8
The semi-auto calibration is a function to see a suggested corrected value of the machine by printing out a
pattern and measuring its dimensions.
9
Press [Print] to print out an embedded pattern.
With the print output attached to the platform, measure X1, X2, Y1, and Y2 as shown in the picture.
10
Adjust each measured value with the slide bar on the screen or by pressing [+] or [-].
Measured values of X1 and Y1 can be entered, ranging from 66.5 mm to 73.5 mm, and changed by 0.01 mm.
On the other hand, measured values of X2 and Y2 can range from 133 mm to 147 mm, and be changed by 0.01 mm.
11
After all measured values are entered, press
[Save]
to save the measured values, and then move to the
previous page.
12
Check the corrected value input, which is suggested with the measured value, and then press
[Save]
to save the
setting values.