Install Instructions
Material Properties of PEX Tubing
TEMPERATURE
HYDROSTATIC
PSI (MAX)
OPERATING
PSI WATER
73.4° F / 23° C 630 160
180° F / 82.2° C 400 100
200° F / 93.3° C 315 80
Operating Pressure / Temperatures
Flow Characteristics
GPM
1/2" PRESSURE
DROP @ 60ºF
(PSI/100FT)
VELOCITY
(F T/SEC)
3/4" PRESSURE
DROP @ 60ºF
(PSI/ ) 100FT
VELOCITY
(F T/SEC)
1" PRESSURE
DROP @ 60ºF
(PSI/100FT)
VELOCITY
(F T/SEC)
1 1.8 1.7 1.2 1.8 .4 1
2 5.9 3.5 2.4 2.7 .7 1.6
3 12.1 5.2 4.0 3.5 1.2 2.1
4 20.1 7 5.7 4.4 1.8 2.7
5 8.1 5.3 2.5 3.2
6 10.7 6.2 3.2 3.7
7 13.5 7.1 4.1 4.3
8 5.0 4.8
9 6.0 5.3
Water Temperature + Water Pressure. PEX tubing
shall not be used in applications where temperature
and pressure ratings are not regulated or are known to
evidence exposures beyond the tested and certied limit
of the tube.
*See individual mfg. instructions for continuous pipe support systems
for large diameter horizontal arterial water mains.
*Additional information found within PowerPEX tubing limitations
Minimum Bend Radius*
TUBE SIZE (CTS) BEND RADIUS
1/2" 3.75"
3/4" 5.25"
1" 6.75"
1-1/4" 8.25"
1-1/2" 9.75"
2" 12.75"
Support + Spacing
TUBE SIZE
HORIZONTAL
SUPPORT SPACING
VERTICAL
SUPPORT SPACING
1/2" 32"
Once Per Floor
Penetration @ oor level
(see pg 33-34). Once at
midpoint of oor expanse
or every 48"
3/4" 32"
1" 32"
1-1/4" 32"*
1-1/2" 32"*
2" 32"*
Material Benefits & Properties
www.siouxchief.com 10