Install Instructions
Sizing
Using manifolds can be accomplished with one of the
previously mentioned plumbing layouts. Typically, the
size of the manifold is dependent on the amount
of xtures it will be supplying. Sioux Chief offers
manifolds with different trunk sizes and in varying
outlet connections and sizes. All outside hydrants
and/or auxiliary xtures fed from their own supply line
would total the branch quantity needed. Some manifold
applications purposefully oversize the manifold by 2
branches for possible future additions. These ‘extra
branches’ are typically sealed off with a plug. If two
xtures within a bathroom or kitchen application can
legally be supplied with a single supply line, the manifold
would reect one less branch.
Location / Accessibility
Typical home run applications should dictate that
a manifold is located near the water conditioning
equipment, utility room, or water heater. This area is
chosen so that the heated water is fed as quickly as
possible to the distribution point for efcient transfer
of conditioned water. In any case, the location chosen
should be readily accessible for service situations.
Manifolds should not be located closer than 3" from a
water heater hot line outlet.
The home run layout has half of the connections at the
manifold itself with the other half located at the stub out
and/or supply stop.
Combination systems allow the cold water distribution
manifold (no valve) to be located in a convenient area
within the structure (no access panels are required for
manifolds without valves).
Branchmaster Manifold Plumbing
Hose Hydrant
Kitchen
Ice Maker
Shower
Toilet
Extra Branch
Extra Branch
Manifold Plumbing
31 www.siouxchief.com