Inc. Power Screwdriver User Manual

Model
5050N5051
Al5050AL
Form
#
Z356D
Serial
"C"
1
/2"
Pistol
Grip
Twin
Hammer
Imoact
Wrenches
-
Operator
Instructions
Important
Read
these
instructions
carefully
before
installing,
operating,
Includes
-
Foreseen
Use,
Work
Stations,
Putting
Into
Service,
servicing
or
repairing
this
tool.
Keep
these
instructions in
a
safe
Operating,
Dismantling,
Assembly
and
Safety
Rules.
accessible
place.
f
Sioux
Tools,
Inc.
1
17
Levi
Drive
Murphy,
NC
28906
U.S.A.
Tel
No.
828.835-9765
Fax
No.
828-835-9685
Produd
Type
1/2"
Pistol
Grip
Twin
Hammer
Impact
Wrenches
Model
No/Nos
5050A
Chrome
Nose
Case
5051
A
Black
Nose
Case
5050AL
2"
Ext.
Anvil
Product
Net
Weight
5050N5051
A
5050AL
5.60
5.80
Ibs
2.50
2.60
Kq
Recommended
Use
Of
Balancer
Or
Support
Air
Pressure
Recommended
Working
6.2
bar
90
PSI
Maximum
6.2
bar
90
PSI
Recommended Hose
Bore
Size
-
Minimum
3/8ins
10mm
Serial
No.
Recommended
Max.
Hose
Length
30Ft
10M
Noise
Level:
Sound
Pressure
Level
89.0
dB{A)
Sound
Power
t-evet
100.0
<tB{A)
Test
Method:
Tested
in
accordance
with
Pneurop
test
code
PN8NTC1
and
IS0
Standard
3744
i
Page
No
1
SAFETY
MESSAGES
Peisonaf
Safety
Equipment
Use
-
Safety
Glasses
YES
Use
-
Safety
Gloves
Use
-
Safety
Boots
Use
-
Breathing
Masks
Use
-
Ear
Protectors
YES
Safety
rules
when
using
5050A,
5051A
and
5050AL
Impact Wrenches
-
Use
only
impact
sockets
and
extensions,
universal
joints,
etc.
rated
as
being
suitable
far
use
with
impact
wrenches.
-
Prolonged
exposure
to
vibration
may
cause
injury.
-Read
all
instructions
before
using
this
toot.
Ail
operators
must
be
fuHy
trained
in
its
use
and
aware
of
these
safety
rules.
-
Do
not
exceed
the
maximum
working
air
pressure.
-
Use
personal
protection
equipment
as
recommended.
-
Some
dust
created
by
power sanding,
sawing,
grinding,
drilling,
and
other
construction
activities
contains
chemicals
known
to
cause
cancer,
birth
defects
and
other
reproductive
harm.
-Use
only
compressed
air
at
the
recommended
conditions.
away
from
the
working
attachment fixed
to
the
tool.
-The
tool
is
not electrically insulated. Never
use
the
too)
if
there
is
any
chance
of
coming
into
contact
with
live
electricity.
-Always
when
using
the
tool, adopt
a
firm
footing
and/or
position
and
grip
the
tool
sufficiently only
to
overcome
any
reaction
forces
that
may
result
from
the
tool
doing
work.
Do
not
overgrip.
-Use
only
correct
spare
parts
for
maintenance
and
repair.
Do
not
improvise or
make
temporary
repairs.
Major
servicing
and
repairs
should
only
be
carried
out
by
persons
trained
to
do
so.
-Do
not
lock,
tape,
wire,
etc.
the
'On/Off'
valve
in
'On'
position.
The
trigger/lwer,
etc.
must always
be
free
to
return
to
the
'Off'
position
when
released.
A
WARNING
Always
Read
Instructions
~efore
using
-TOOIS
@
NGw-v
Wear
Hearing
Protection
Amid
Prolonged
Exposure
A
mmm
Vibration
Level
(5050A15051
A)
4.0
Meters
1
Sec2
(5050AL)
4.3
Meters
I
Sec2
Test
Method:
Tested
in
accordance
with
IS0
standards
8662
Parts
1
&
7
-If
the
tool
appears
to
malfunction,
remove
from
use
immediately and
arrange for
service
and
repair.
If
it
is
not
practical
to
remove
too!
from
service,
then
shut
off
the
air
supply
to
the
tool
ft!
Pipa
And
Fittings
swH
bw
and
write
OF
have
written
a
warning
note
and
attach
it to
the
toot.
-
If tool is
to
be
used with
a
balancer
or
other
suspension
device,
ensure
that
the
tool
is
firmly
attached to
the
suspensiodsupport
device.
When
operating
the
tool,
always
keep
the
body
and particularly the hands
Recommended
Air
Supply
System
Figure
1

Summary of content (20 pages)