Installation Guide

SIRIUS Through Roof EasyKITs – EASYROOF150T/Mand
“EASYROOF200T/M”
Sirius ducting kits are a high quality and simple, complete solution in a box. They provide an
ideal ventilation path to efficiently exhaust your kitchen fumes, steam, heat and odours
filtered through your rangehood to the outside atmosphere.
There are 2 ducting sizes available 150mm and 200mm. Please choose the correct size for
your rangehood and also that you specify for either a tiled or metal roof.
Please check that there is a clear
path for your ducting to run prior to installation, making sure
to look out for TV, computer, telephone and electrical cables, water and gas pipes, insulation
materials and air conditioning pipes and duct, before cutting holes.
For new homes, ideally fit the basic ducting (pipe) components at the frame up stage.
Additional lengths of ducting, joins, galvanised steel angled elbows and all other ducting
access
ories are available
SIRIUS EasyKIT.
from your local retailer, or Sirius online where you purchased your
For further advice please call our ducting consultation service on Ph: 1300 762 219 (Australia
only) or visit www.siriusbrand.com
and fill in the fields and one of our trained consultants will
assist you in the best manner possible.
Each EasyKIT comes complete with the following components, ready to be installed by a
suitably qualified and licensed tradesperson.
1 x 3m of Semi-Rigid PLUS aluminium ducting (SRPRO30/150 or SRPRO30/200)
1 x 1m of solid galvanised steel pipe (GP12-150 or GP12-200).
1 x *Silicone and soft form Aluminium roof flashing for either a tiled or metal roof.
1 x galvanised steel roof cowl (GRC-150 or GRC-200)
Tiled roof (TRFG075), Metal roof (MRF-G102)
1.5m galvanised steel, perforated bracing strap (GBS-200).
2 x galvanised steel duct connectors with double EPDM gasket seals (GDC150-GDC200).
2 x stainless steel ring clamps.
# Please note: We don’t supply silastic sealants, self-sealing fasteners (roofing screws), nails or wood screws for the bracing
strap… as most qualified trades people have these on board and will use whatever is appropriate for your buildings materials.
Installation Guide
:
(Disclaimer) The following instructions are provided as a guide only and in no way constitute or replace your local council requirements or Australian and New Zealand Standards and Building Codes.
1. Remove the required roofing tiles or cut the appropriate sized hole through the metal roof, being careful to watch out for insulation, cables, etc. (as above)
2. Using sharp tin snips, carefully trim the silicone cone to the correct pipe diameter. Wet the pipe with a water sp
ray as a lubricant and carefully fit over the
top and slide halfway down the pipe.
Please note: if done correctly this will provide a very efficient seal to repel moisture. Should you accidentally over cut
the silicone cone, use an additional (3
rd
) ring clamp to draw in the silicone cone around the pipe.