Operating Instructions
Table Of Contents
- Table of contents
- 1 Dear Customer,
- 2 General data
- 3 General description
- 4 Safety
- 5 Installation and startup
- 5.1 Transport and unpacking
- 5.2 Disposal of packaging materials
- 5.3 Installation site
- 5.4 Commissioning
- 5.4.1 Functional elements
- 5.4.2 Supplied tools
- 5.4.3 Touch display description
- 5.4.4 Illumination of the processing chamber, LED light strip, and On/Off button
- 5.4.5 Using the processing chamber screen
- 5.4.6 Installation
- 5.4.6.1 Connecting to the PC via LAN
- 5.4.6.2 Connecting the unit to the power supply
- 5.4.6.3 Installing the unit
- 5.4.6.4 Connecting the suction device (optional)
- 5.4.6.5 Connecting to the PC via WLAN (option)
- 5.4.6.6 Operating several production units at one access point
- 5.4.6.7 Connecting to the PC via the wireless interface (optional)
- 5.4.7 Filling the water tank
- 5.4.8 Switching the unit ON and OFF
- 5.5 Repacking
- 5.6 Scope of supply
- 5.7 Storage
- 6 Operation
- 7 Service
- 7.1 Using the cleaning hose and the wet cleaning process
- 7.2 Changing filter bags and HEPA filters
- 7.3 Changing the water
- 7.4 Instruments
- 7.5 Care, cleaning agents, and disinfectants
- 7.6 Cleaning surfaces
- 7.7 Replacing the main fuses
- 7.8 Changing the filter
- 7.9 Removing water from the unit
- 7.10 Using the tank cap opener
- 8 Technical description
- 9 Disposal
- 10 Consumable
- Index
Dentsply Sirona
Operating Instructions CEREC Primemill
6 Operation
6.4 Manual block clamp
67 19 756 D3439
D3439.201.01.01.0209.2019
47
6.4
Manual block clamp
Keep the clamp tool in the associated holder.
NOTE
Wear of the ball pressure screw
The high clamping forces cause wear of the ball pressure screw.
➢ Replace the ball pressure screw every 500 clamping operations.
Blocks with 6 mm diameter block holders
NOTE
Fasten the block tightly
If the block is not sufficiently tightened, it can lead to unsuitable
results and ceramic breakages.
➢
Securely tighten the block with the block clamping tool with the
torque wrench, until you can hear a clicking sound.
➢ Check to make sure that the block is seated very firmly.
1.
Insert the adapter sleeve (
A
) into the block fixing.
NOTE
Insert the adapter sleeve
The slot at the bottom end of the adapter sleeve must lie above the
radial pin of the block fastener in order to be inserted fully.
The hole for the ball pressure screw is then automatically in the
correct position, i.e. coincides with the threaded hole in the block
fixing.
2.
Insert the block (
B
) into the adapter sleeve.
3. Clamp
the ceramic block
securely
with the ball pressure screw (
C
).
Use the block clamp tool with torque wrench for this purpose.