Operating Instructions
Table Of Contents
- Table of contents
- 1 Dear Customer,
- 2 General data
- 3 General description
- 4 Safety
- 5 Installation and startup
- 5.1 Transport and unpacking
- 5.2 Disposal of packaging materials
- 5.3 Installation site
- 5.4 Commissioning
- 5.4.1 Functional elements
- 5.4.2 Supplied tools
- 5.4.3 Touch display description
- 5.4.4 Illumination of the processing chamber, LED light strip, and On/Off button
- 5.4.5 Using the processing chamber screen
- 5.4.6 Installation
- 5.4.6.1 Connecting to the PC via LAN
- 5.4.6.2 Connecting the unit to the power supply
- 5.4.6.3 Installing the unit
- 5.4.6.4 Connecting the suction device (optional)
- 5.4.6.5 Connecting to the PC via WLAN (option)
- 5.4.6.6 Operating several production units at one access point
- 5.4.6.7 Connecting to the PC via the wireless interface (optional)
- 5.4.7 Filling the water tank
- 5.4.8 Switching the unit ON and OFF
- 5.5 Repacking
- 5.6 Scope of supply
- 5.7 Storage
- 6 Operation
- 7 Service
- 7.1 Using the cleaning hose and the wet cleaning process
- 7.2 Changing filter bags and HEPA filters
- 7.3 Changing the water
- 7.4 Instruments
- 7.5 Care, cleaning agents, and disinfectants
- 7.6 Cleaning surfaces
- 7.7 Replacing the main fuses
- 7.8 Changing the filter
- 7.9 Removing water from the unit
- 7.10 Using the tank cap opener
- 8 Technical description
- 9 Disposal
- 10 Consumable
- Index
Dentsply Sirona
Operating Instructions CEREC Primemill
3 General description
3.2 Intended use
67 19 756 D3439
D3439.201.01.01.0209.2019
9
3.2
Intended use
The Sirona Dental CAD/CAM System is intended for use in partially or
fully edentulous mandibles and maxillae in support of single or
multipleunit cement retained restorations. For the BH 3.0 S, SSO 3.5 L
and SBL 3.3 L titanium bases, the indication is restricted to the
replacement of single lateral incisors in the maxilla and lateral and
central incisors in the mandible. The system consists of three major
parts: TiBase, inCoris mesostructure, and CAD/CAM software.
Specifically, the inCoris mesostructure and TiBase components make
up a two-piece abutment which is used in conjunction with endosseous
dental implants to restore the function and aesthetics in the oral cavity.
The inCoris mesostructured may also be used in conjunction with the
Camlog Titanium base CAD/CAM (types K2244.X)(XX) (K083496) in
the Camlog Implant System. The CAD/CAM software is intended to
design and fabricate the inCoris mesostructure. The inCoris
mesostructure and TiBase two-piece abutment is compatible with the
following implant systems:
Manufacturer Name of Implant
System
Implant Size
Platform Diameter Length
Nobel Biocare Replace NP 3.5 10mm – 15mm
RP 4.3 10mm – 18mm
WP 5.0 10mm – 18mm
6.0 6.0 10mm – 18mm
Active NP 3.5 8.5mm – 18mm
RP 4.3/5.0 8.5mm – 18mm
Branemark NP 3.3 10mm – 15mm
RP 3.75/4.0 7mm – 18mm
Straumann Synocta NN (3.5mm) 3.3 8mm – 16mm
RN (4.8mm) 3.3/4.1/4.8 4mm – 16mm
WN (6.5mm) 4.8 4mm – 14mm
Bone Level NC (3.3mm) 3.3 8mm – 16mm
RC (4.1mm/4.8mm 4.1/4.8 8mm – 16mm
Dentsply Sirona
Implants
Osseospeed 3.5/4.0 3.5 S / 4.0 S 6mm – 17mm
4.5/5.0 4.5/5.0/5.0 S 9mm – 17mm
Xive 3.4 3.4 9.5mm – 18mm
3.8 3.8 8mm – 18mm
4.5 4.5 8mm – 18mm
5.5 5.5 8mm – 15mm
Osseospeed EV 3.6 3.6 6mm – 17mm
4.2 4.2 6mm – 17mm
4.8 4.8 6mm – 17mm
5.4 5.4 6mm – 15mm
Ankylos C/X A, B, C, D 8mm – 17mm