3. Open Mission Planner, select the correct COM port for HM30 ground unit and
configure the baud rate.
4. The Type-C datalink connection to Mission Planner is established.
Mark
If the HM30 ground unit cannot be recognized as a COM device by your Windows device,
please open “Computer Manage Device Manager” and check if there were any abnormal
drivers. If so, please download and install the relevant drivers to solve the issue.
4.5 Solutions to Disconnection
If HM30 system failed to establish the datalink connection with the GCS, please try
to follow the steps below to investigate possible reasons.
1. Confirm if the HM30 air unit is connected to your flight controller through the
correct telemetry cable.
2. If it is a DIY telemetry cable, please check:
If the correct pin map is followed?
If the “TX” pins go to the “RX” pins?
If any of the wires are defect?