Spec Sheet
TANK ALERT
®
EZ Alarm System
Innovative, indoor or outdoor liquid level alarm system.
OPTIONS
When ordered with the alarm, the system is available with:
n
alternateoatswitchmodelsforhighorlowliquidlevelwarning.
n
premountedterminalblocksoenclosurecanalsobeusedasa
junctionboxforsplicingpump,pumpswitch,andpumppower.
MeetsNECstandardforjunctionboxes.
n
6foot(1.8meter)powercordwith120VACplugandliquidtight
connector(120VModelonly).
FEATURES
n
2-colormoldedenclosureoffersadistinctlook;uppertranslucenthalf
illuminatesinalarmcondition.
n
Removablelowercoverprovidesgreateraccessforeasiereldwiring
whiletheinternalcircuitryremainsprotected.
n
Interlockingenclosurefeaturesuniquesoundchambertoamplifythe
horn,whilehelpingpreventmoisturefromentering.
n
Externalmountingtabsforeasyinstallation.
n
EnclosuremeetsType3Rwater-tightstandards.
n
Enclosurehasindicatormarksonbottomforeasyplacementofcord
entrylocations.
n
Automaticalarmreset,hornsilenceswitch,andalarmtestswitch.
n
Alarmhornsoundsat82decibelsat10feet(3meters)
n
Alarmsystem(wheninstalledonseparatecircuit)operatesevenif
pumpcircuitfails.
n
Greenpoweronindicator.
n
Includesauxiliaryalarmcontactsforeasyattachmentofremotedevices.
n
CompletepackageincludesstandardSJESignalMaster
®
controlswitch
with15feet(4.57meters)ofcable(otherlengthsavailable)andmounting
clamp.
n
CSACertied.
n
Five-yearlimitedwarranty.
Thisalarmsystemmonitorsliquidlevelsinliftpumpchambers,sumppumpbasins,holdingtanks,
sewage,agricultural,andotherwaterapplications.
TheTank Alert
®
EZindoor/outdooralarmcanserveasahighorlowlevelalarmdependingontheoat
switchmodelused.Thiseasytoinstallalarmfeaturesaninnovative,sleek2-colormoldedenclosure
whichintegratestheLEDredtranslucentbeacon.
Thealarmsoundsandtheupperhousinghalfilluminateswhenapotentiallythreateningliquidlevel
conditionoccurs.TheaudiblealarmcanbesilencedbypressingtheTest/Silencebutton,butthe
alarmlightwillremainonuntiltheconditionisremedied.Oncetheconditioniscleared,thealarmwill
automaticallyreset.Agreen"PowerOn"lightindicatespowertothealarmpanel.
SPECIFICATIONS
VOLTAGE:
120 VAC Model:
Primary:120VAC,50/60Hz,3.8watts
max.(alarmcondition)
Secondary:9VDC
240 VAC Model:
Primary:240VAC,50/60Hz,3.8watts
max.(alarmcondition)
Secondary:9VDC
ALARM ENCLOSURE: 6.7x5.3x2.5inch
(17.02x13.46x6.35cm),indoor-outdoor,
weatherproof,thermoplasticmeetsType
3Rwater-tightstandard
ALARM HORN:82decibelsat10feet
(3meters)
AUXILIARY ALARM CONTACTS: 240VAC/
30VDC,1.5ampsmax.,50/60Hz(circuit
notsupervised)
PRE-MOUNTED TERMINAL BLOCK
(OPTIONAL):20amps,120/240VAC
POWER CORD
(OPTIONAL - 120V MODEL ONLY):
6foot(1.8meter)cordwith120VACplug
FLOAT SWITCH: SJE SignalMaster
®
control
switchwithmountingclamp
Cable:15feet(4.57meters),exible18
gauge,2conductor(UL)SJOW,water-
resistant(CPE)
Float: 2.74inchdiameterx4.83inchlong
(7cmx12.3cm),highimpact,corrosion
resistantpolypropylenehousingforuse
insewageandnon-potablewaterupto
140
o
F(60
o
C)
Maximum Water Depth: 30feet
(9meters),13PSI
Electrical: 5amps,125VAC/250VAC,
50/60Hz
SEE BACKSIDE FOR ORDERING INFORMATION.
POBox1708,DetroitLakes,MN56502
1-888-DIAL-SJE•1-218-847-1317
1-218-847-4617Fax
email:customer.service@sjerhombus.com
www.sjerhombus.com
U.S.PatentNos.8,737,672andD695,640