User's Manual

Table Of Contents
INTEGRATION WITH SKF @PTITUDE OBSERVER
Hierarchy view adding sensors and measurements
24 (92)
SKF Enlight Collect IMx-1 System
User Manual
Revision C
Not active, Outside measurement range, Transient, Outside active range and
Outside active range unstable.
In addition the Cable fault icon is, for the IMx-1, used to indicate that a sensor is
unreachable, ‘Sensor not available’. For further information on the priority of IMx-1
status indications in an @ptitude Observer hierarchy, refer to the SKF @ptitude
Observer user manual or help file.
Notes on hierarchy operations:
IMx-1 sensor nodes can only be added to a sub-machine.
Neither IMx-1 measurements nor IMx-1 sensor nodes can be copied by using
the ‘standard’ copy mechanisms, but they are included when using the
Machine Copy Wizard.
o The assigned gateway will not be copied, during the copy process the
user will be asked to select a gateway or ‘None’, for this copied
machine.
Users can drag and drop an IMx-1 sensor node but only within the asset and
on the same hierarchy level.
Users can only drag and drop an IMx-1 measurement point within its sensor
node.
To open up the properties of an existing sensor node, right click and select
Properties or double click.
Figure 11 IMx-1 sensor dialog example