INTEGRATION WITH SKF @PTITUDE OBSERVER
IMx-1 system configuration
SKF Enlight Collect IMx-1 System
User Manual
Revision C
33 (92)
be specified by either an IP address or a DNS naming related, for example, to a web
service provider’s domain.
See also TCP and UDP Port Usage.
NTP settings indicate to the gateway where an NTP server can be contacted. An
entry for at least the ‘Primary’, is required before the configuration can be saved. Like
other IMx devices, in Database > Options > Device settings tab, time synchronisation
thresholds can be configured to generate system alarms if time synchronisation is
lost.
Status information when/as it is available, is presented on the Gateway status tab:
Figure 19 Gateway properties – Gateway status tab
The status tab feeds back information on Hardware revision and Firmware
version, gateway Internal temperature, its Self-diagnostics status, WiFi SSID and
Signal strength and when Created/First connection/Status updated, firmware
Build number. Note the information provided is updated on opening the dialog box,
not in real time.
Important Note: the gateway allocation to a particular machine or machines is set on
the Machine Properties > Enlight Collect IMx-1 System tab, and must be allocated
before commissioning: