User's Manual

Parking Column 1
Parking Column for System SPT 400 1.2
© SKIDATA AG, Version 1.0 Page 11
Caution:
The OUT terminal on connection control board sd591 is not
fused and cannot be deactivated by way of the on-board mains
switch.
Note:
Electrical leads and wires must comply wirth applicable na-
tional guidelines concerning
– mechanical stress
– tension resistance
– cross-sectional area with respect to voltage drop
– current carrying capacity and short-circuit rating
To install electrical fittings, you must first remove the cover of
control board sd591
1.2.4 Cross-sectional area of cable leads
1.2.5 Connection terminals for control lead and
intercom
Tab. 1: Cable leads – Technical characteristics
wires Max. torque at terminals Rigid
Solid
Flexible
Twisted
* 0,22 – 0,25 Nm 0,14 – 1,5 mm² 0,14 – 1,5 mm²
** 0,5 – 0,6 Nm 0,20 – 2,5 mm² 0,20 – 2,5 mm²
*** 0,22–0,25 Nm 0,14 – 1,5 mm² 0,14 – 1,0 mm²