Lubrication
The gear case has been completely lubricated at the factory.
However, after six months to one year, depending upon use, it’s
wise to return your tool to the nearest Service Center for the
following:
Brushes replaced.
Parts cleaned and inspected.
Relubricated with fresh lubricant.
Electrical system tested.
All repairs.
The following parts should be oiled occasionally with SAE No. 20 or
No. 30 oil, or WD 40.
1. Elevation, support rods, and gears.
2. Sliding rails and supports.
3. Table locking cams (Front & Rear).
Make sure the teeth of the ANTIKICKBACK pawls are al ways
sharp. To sharpen:
1. Remove blade guard.
2. Rotate pawl toward rear of spreader so that teeth are above
top of spreader.
3. Hold spreader with pawl over corner of workbench (Fig. 57).
4. Using a small round file (Smooth Cut) sharpen the teeth.
All repairs, electrical or mechanical, should be
attempted only by trained repairmen. Contact the
nearest Factory Service Center or Authorized Service Station or
other competent repair service. Use only identical replacement
parts, any other may create a hazard.