Install Instructions

Page 17
How to Maintain Your Humidier
DANGER: To avoid electrical shock or burn, turn
off the power supplying this equipment before
servicing.
To maintain high evaporating efciency of your Model 55 or Model 86
humidier, replace the evaporator pad at least once a year (e.g., at the end
of each heating/humidifying season). In hard water areas, cleaning may
be required every three-to-four weeks; in soft water areas, cleaning may
be required every four-to-eight weeks.
At the end of each humidication season (i.e., in the spring), clean the
humidier thoroughly, and turn off the water and electrical power to the unit
until the following season.
CAUTION: Do not leave water in the humidier pan
over the non-humidifying months!
For standard maintenance of Model 55, follow these instructions:
Shut off the water supply.
Lift out the distribution tray and evaporator pad assembly by reversing
the procedure found in #2 under “Installing the Humidier Pan (Model
55)”, page 11.
Wash all plastic and metal parts (except electrical parts) in humidier
cleaner or a 50/50 solution of vinegar and water. Rinse all parts
thoroughly with fresh water.
Wipe loose sediment from the water tray.
CAUTION: Make sure no particles are allowed to plug
the drain hole.
Replace the evaporator pad.
NOTE: Annual replacement of the evaporator pad is
recommended. Severe clogging of the pores may require
replacing the pad more frequently.
Restore the humidier to automatic operation mode by following the
nal assembly instructions for Model 55 on page 11.
1.
2.
3.
4.
5.