Use Instructions

F401-01(A-190102) Sky Labs Inc.
CHAPTER 12. Information on EMC
1. Guidance and Manufacturer’s Declaration – Electromagnetic Emissions
- The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT
should assure that it is used in such an environment.
Immunity test
Compliance
Electromagnetic environment - Guidance
RF Emissions CISPR 11
Group 1
The EUT uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to
cause any interference in nearby electronic equipment.
RF Emissions CISPR 11
Class A
The EUT is suitable for use in all establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings
used for domestic purposes.
Harmonic emissions IEC
61000-3-2
A
Voltage fluctuations / Flicker
emissions IEC 61000-3-3
Complies
2. Guidance and Manufacturer’s Declaration – Electromagnetic Immunity
- The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT
should assure that it is used in such an environment.
Immunity test
IEC 60601
Test level
Compliance
Electromagnetic environment - Guidance
Electrostatic discharge
(ESD)
IEC 61000-4-2
±8kV Contact
±2kV, ±4kV, ±8kV,
±15kV air
±8kV contact
±15kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should
Electrical fast
transient/burst
IEC61000-4-4
±2kV
100kHz repetition
frequency
±2kV
100kHz repetition
frequency
Mains power quality should be that of a
typical commercial or hospital
environment.
Surge Line-to-line
IEC 61000-4-5
±0.5kV, ±1kV
±1kV
Mains power quality should be that of a
typical commercial or hospital
environment.
Surge Line-to-ground
IEC 61000-4-5
± 0.5kV, ± 1kV,
±2kV
±2kV
Voltage dips
IEC 61000-4-11
0 % UT; 0,5 cycle
At , 45°, 90°,
135°, 180°, 225°,
270° and 315°
0 % UT; 0,5 cycle
At , 45°, 90°, 135°,
180°, 225°, 270° and
315°
Mains power quality should be that of a
typical commercial or hospital
environment. If the user of the EUT image
intensifier requires continued operation
during power mains interruptions, it is
recommended that the EUT image
intensifier be powered from an
uninterruptible power supply or a battery.
Voltage interruptions
IEC 61000-4-11
0 % UT; 1 cycle
and 70 % UT; 25/30
cycles
Single phase: at 0°
0 % UT; 1 cycle
and 70 % UT; 25/30
cycles
Single phase: at 0°