Installation Guide

QUICK GUIDE
www.skylinkhome.com
Testing the Battery
Battery Status
Charging the Battery
Troubleshooting
Installation
Install the Metal Hanger - EQ/IQ Series Connecting the Battery Backup - EQ/IQ Series
Battery Backup
Model: BA-100
Battery Backup Unit
(12V Sealed Lead Acid
battery included)
Mounting
Accessories
2-Wire Harness (Fused)
(The cord included is with
connectors at each end)
Cushion Users Instructions
WARNING!
To reduce the risk of severe injury or death:
- Disconnect electrical power to the garage door
opener before servicing or repairing.
- Dispose of used battery properly.
1. Press the latch inwards to release the cover.
The battery unit will take 24 hours to fully charge.
A fully charged battery provides 24VDC to the garage
door opener for 1 to 2 days of normal operation
during AC power outages. When the battery level drops
too low, the battery unit will no longer operate.
If the opener does not provide the charging feature, plug
in an AC adapter (sold separately) to charge the battery.
Please contact Skylink to purchase the AC adapter.
The battery life is about 3 to 5 years for normal usage.
To obtatin maximum battery life and prevent any
damage, turn off the Battery Backup Unit when the
garage door opener is supposed to be unplugged for
a long period of time.
Note: Door operation may be limited if the battery is
not fully charged, or the garage door opener light
may not turn on during battery operation.
1. Why can’t I operate my opener with a BA-100?
Make sure the BA-100 is fully charged.
2. Can I use BA-100 to operate other brands of
an opener?
BA-100 is designed to work with Skylink openers only.
3. Can I charge the BA-100 with my opener?
You can use the AC adapter (sold separately) to charge
the BA-100.
4. Why does the light stay off when I use the BA-100
to operate the opener?
The opener light will not turn on during the battery
operation.
Red LED
ashing
slowly
Fully charged
(AC adapter is
unplugged)
Backup battery
is weak (AC
adapter is
unplugged)
Backup battery is
being charged
(AC adapter is
plugged in)
Fully charged
(AC adapter is
plugged in)
Backup battery is
not installed
(AC adapter is
plugged in)
or switch is not
turned on
Garage Door
Opener is being
affected by power
outage
Garage Door
Opener will operate
in ‘battery backup’
mode
Ready to provide
power to garage
door opener
Needs to
re-charge
Charging
Ready to use
Re-install the
backup battery.
Turn the switch
on. Check conn-
ection between
batter
y and 2-wire
harness.
Blue LED
ashing
slowly
White LED
ashing 3
times quickly
Blue LED
ashing
quickly
and white
LED ashing
slowly
Red LED
staying on
Blue LED
staying on
Take out the battery and connect the wires to the battery
terminal tabs, being careful to match the polarity.
2. Remove the cover.
7. Close the cover.
What’s in the Box?
3.
Install the Metal Hanger - ATOMS Series
Warranty
1
3
2
4. Red wire connects to red terminal tab.
6. Place the battery back into battery compartment.
5. Black wire connects to black terminal tab.
4
5
UNPLUG THE GARAGE DOOR OPENER FROM
POWER BEFORE PROCEEDING!
Use the screws and nuts
to mount the metal hanger
to the operator mounting
plate.
1
Affix a cushion at the side
of the hanger.
2
Install the backup battery
unit to the metal hanger.
3
Important Note: These next two steps must be
performed in this exact order very carefully to
prevent a short in the battery by accident.
Connecting the battery backup unit to the garage
door opener unit:
1. Connect the 2-wire harness to the garage door
opener unit, being careful to match the polarity.
2. Insert the 2-wire harness to the battery backup unit.
Red wire connects to
the “+” terminal.
Black wire connects to
the “-” terminal.
UNPLUG THE GARAGE DOOR OPENER FROM
POWER BEFORE PROCEEDING!
Use the screws and nuts
to mount the metal hanger
to the operator mounting
plate.
1
Affix a cushion at the side
of the hanger.
2
Install the backup battery
unit to the metal hanger.
3
1
2
Connecting the Battery Backup - ATOMS Series
Important Note: These next two steps must be
performed in this exact order very carefully to
prevent a short in the battery by accident.
Connecting the battery backup unit to the garage
door opener unit:
1. Connect the 2-wire harness to the garage door
opener unit, being careful to match the polarity.
2. Insert the 2-wire harness to the battery backup unit.
Note: The battery backup must be fully charged for
24 hours before testing or operation.
1. Turn on the battery backup switch.
2. Unplug the garage door opener from the AC power.
4. Plug the garage door opener back in.
3. Activate the garage door opener. (The lamp in the
garage opener will not light up).
1
2
3
If, within one year from date of purchase, this
product should become defective (except battery),
due to faulty workmanship or materials, it will be
repaired or replaced, without charge. Proof of purchase
and a Return Authorization Number are required.
Need help?
Visit our website or call our Customer Service
9:00am - 5:00pm EST, Monday-Friday
1-800-304-1187
WWW.SKYLINKHOME.COM
Turn on the backup battery switch, and connect the backup battery
with the GDO correctly.
Status Action
Light Status
www.skylinkhome.com
Note: The garage door opener EQ/IQ series requires
an AC adapter (sold separately) to charge up the battery.
Please contact Skylink for information regarding the AC
adapter (Item # 900046).
1
2
P/N : 101Y071-001 Rev. 1
3. The ATOMS will automatically charge the battery
when the opener is plugged in.
Refer to the lights indication section above to check the
battery status.

Summary of content (1 pages)