Instructions / Assembly

24
Below is a table summarizing all the preprogrammed sequences.
Sequence Zone 1 Zone 2 Zones 3 & 4 When sequence should be used
FOR TESTING
MPIN A # chime chime chime use for testing after installation
and to test batteries, also use as
a subtle chime when a remote
sensor has been activated
BASIC PROGRAMMING
MPIN B C exit delay off instant use when leaving the premises
(after 45 sec.)entry delay entry delay instant and no one is inside
MPIN C exit delay off instant use when leaving the premises
(after 45 sec.) and someone is inside the
premises
MPIN A B instant off instant use when people are in the
premises and no one is expected
to enter/exit
MPIN # off off off turns off the system
Note: when MPIN # is enter and the system is already off, the system will default
back to the last sequence before the unit was shut off
ADVANCED PROGRAMMING
MPIN A A entry delay off instant someone is in the building and
someone is expected to enter/
no exit delay
MPIN A C entry delay entry delay instant person staying in the premises
is setting the alarm and will not
walk in the area monitored by the
motion detector
Panic button - The SC-100 has 2 panic buttons, (the red buttons on the keychain
transmitter and on the Control Panel). The alarm will sound instantly when either
of these buttons are pressed whatever mode you are in.
Emergency Silent Alarm (works in conjunction with the Emergency Dialer option) -
When disarming the system under duress, enter your MPIN, then press [ B ], [ B ].
This will terminate the delay mode and return to the previous arm mode, as well
as send a signal to the Emergency Dialer, which will then send pre-recorded
messages for help. Do not activate this sequence if your Skylink security system
contains the Audio Alarm AA-433. Since it will sound the siren of the AA-433
instantly.
SUMMARY OF ARMING SEQUENCES
25
The SC-100 Security System comes with 5 batteries that at some point you may
have to replace:
1 9 volt alkaline battery for the Control Panel
1 9 volt alkaline battery for the Motion Sensor
2 12 volt alkaline batteries for the 2 Door/Window Sensors
1 12 volt alkaline battery for the Keychain Transmitter
Recommendation: Test you system periodically to ensure that all batteries are
working.
CONTROL PANEL BATTERY
The Control Panel comes equipped with a backup battery in case the electrical
power is interrupted for any reason.
When the Control Panel battery is low, the LOBATT. light goes on. Also, when the
LOBATT. light is on and if you press any key on the keypad, 10 beeps warn you
that the battery needs to be changed.
To replace the Control Panel backup battery:
1. Disarm the unit.
2. Open the Control Panel case by pressing
down on the two tabs on the top edge and
pull the front forward.
3. Disconnect the old battery.
4. Connect the new battery.
5. Close the Control Panel.
Note: To guard against sabotage, the Control Panel is equipped with an emer-
gency switch that activates the alarm instantly when the case is opened. Make
sure that the unit is disarmed when you open the case or you will activate the
alarm.
The battery life, (9 volt alkaline battery), is approximately two years if used only
for backup.
BATTERY MAINTENANCE