Determine the appropriate measurement distance from your target. 
Best  measurements  are  made  when  the cup  is  in  contact  with  the  target,  so  that  the  infrared 
sensor’s field of view is fully focused on the object. 
Change display measurement units.
Turn on the device by pressing the “MEASURE” button, then simply press the “°C/°F” button, and 
the unit of measure shown on screen will be changed from Celsius to Fahrenheit or vice versa.
GENERAL OPERATION
THIS  WARRANTY  IS  ONLY  VALID  IN  THE  COUNTRY  OF  PURCHASE  AND  THROUGH  FORMAL 
DISTRIBUTOR. 
We guarantee  this  product to be free of manufacturing and assembly defects  for a period of one year 
from  the  time  of  purchase.  The  warranty  only  applies  to  material  or  operational  defects,  which  are 
present at the time of purchase. During that period, we will repair or replace free of service charge for 
products deemed defective due to those causes.
For any repair or replace service, please contact your dealer in the first instance, who is responsible for 
processing guarantee claims. This warranty is not valid for any damage or subsequent damage arising 
as  a  result  of  misuse,  modification  or  as  a  result of  failure  to  observe  the  procedures outlined  in  this 
manual.
WARRANTY AND SERVICE
3. 
4. 
In general, if you are not comfortable to change emissivity value, it is best NOT to change it. Factory 
default  emissivity  value  is  0.95  which  will  provide  accurate  temperature  measurements  for  most 
materials. 
To  change  emissivity  setting,  first  turn  on  the  gauge  on  by  pressing  the  “MEASURE”  button,  and 
hold “MODE” + “°C/°F” buttons simultaneously. The emissivity value on the screen will blinking.
Push  “MODE”  button  to  increase  emissivity  value  and  push  “°C/°F”  button  to  decrease  emissivity 
value.
Aluminum Anodized
Plastics
Rubber, hard glossy plate
Carbon pressed filled surface
0.77
0.91
0.94
0.98
SURFACE MATERIAL
EMISSIVITY COEFFICIENT
SPECIFICATION
Operation Voltage: AAA battery X 2
Operation Current: ≤40ma@2.0V
Operation Temperature: 0-40℃
Current Drain: ≤25ua@3V
Precision: -40℃-0℃ +/-1℃ 0℃-60℃ +/-0.5℃ 60℃-120℃ +/-1℃
 120℃-180℃ +/-2℃ 180℃-240℃ +/-3℃ 240℃-360℃ +/-4℃
Adjustable Range for Infrared Emission Frequency: 0.01-1
Dimension: 121x40x39.6mm
Weight: 75g
Emissivity Coefficients of some common Materials for RC products
The emissivity of a material (usually written  ) is the relative ability of its surface to emit energy by 
radiation. It is the ratio of energy radiated by a particular material to energy radiated by a black body 
at the same temperature. Different types of materials have different emissivity values. 
5. Change emissivity coefficient value. 
ε
2. Battery replacement
When the  battery  power  indicator  is  low, you  should  change battery  immediately.  Low  battery will 
affect the accuracy of measurement. Open the battery compartment and replace 2 X AAA battery. 
Full Battery Partially Full Battery Low Battery
1. Battery installation
This thermometer is powered by 2 x AAA batteries. (Battery Excluded)
With thumbs on battery compartment cover push down and slide. 
Push
Slide