User Manual

· 34
MC3000
3. Press ‘Details’ on the screen to viewgraphs and slot operation details, such as Battery Voltage,
Current, Temperature, Resistance etc., in a single overview. The battery icon is for switching the
view between slots.
4. Pressing the slot number button will stop the operation of the program in that slot.
35 ·
MC3000
ERROR MESSAGE
In case of abnormal program termination or other ordinary error the screen will display the cause
of error and emit an audible sound.
User-set capacity cut-off value has been reached. Set it higher or OFF.
User-set total time limit has been reached. Set it higher (<24h) or OFF.
User-set battery temperature has been reached. Set it higher or OFF.
Internal temperature alarm has been triggered. Stop all and cool off.
The battery connection of a busy slot got interrupted. Check the
connections and question the battery health.
The input voltage is below 11V. Connect proper power supply or in
GSV lower the parameter of the Input option.
The input voltage is above 18V. Disconnect power and connect proper
power supply.
No such warning when a battery is connected incorrectly. Don't fool
around.
No such warning when a slot is short-circuited. Don't mess around.
Voltage of inserted battery seems off, mismatches the program for the
slot. Check BATT TYPE in your program settings, or try a Factory Reset.
Note that the minimum accepted voltage is 0.2V and the maximum
voltage per slot must not exceed 5.0V.
User calibration of the slot seems totally off. Perform Calibration Reset
in GSV to prevent potential damage.
The ventilation fan was supposed to start but there is no current flow.
Check connection to PCB, check fan.
Bad condition cells or batteries with high internal resistance may be
rejected.
Spontaneous extraordinary internal error of unknown origin and
magnitude, sneaky bug, thanks for your comprehension. Ignore or
unplug from mains.
§$%&ß”#wth!
Capacity Cut
Timer Cut
BattTemp Cut
SysTemp Too Hot
Connection Break
Input Volt Too Low
Input Volt Too Hi
Reverse Polarity
Short Circuit!
Check Voltage
Calibration Err
Fan Disconnect Err
Battery So Poor
unknown err thx
UnhandledException
BLUETOOTH APP
Mode
Status
Capacity
Voltage
Current
Time
Temp.
LiIon
Charge
3 mAh
4.32 V
1.00 A
00:00:18
27
1 2 3 4
Details
SkyRC MC3000
:
:
:
:
:
:
:
15:53
Revo
LiIon
Charge
3 mAh
4.23 V
1.00 A
00:00:18
29
LiIon
Charge
0 mAh
3.90 V
0.15 A
00:00:18
28
LiIon
Charge
2 mAh
3.57 V
0.50 A
00:00:18
27
Mode
Status
Capacity
Voltage
Current
Time
Temp.
LiIon
Charge
3 mAh
4.32 V
1.00 A
00:00:18
27
1 2 3 4
Details
SkyRC MC3000
:
:
:
:
:
:
:
15:53
Revo
Charge
0 mAh
4.23 V
0.00 A
00:00:00
29
LiIon
Charge
0 mAh
3.90 V
0.15 A
00:00:18
28
LiIon
Charge
2 mAh
3.57 V
0.50 A
00:00:18
27
2 3 4
4.40
4.26
4.12
3.68
3.84
3.70
Time:
Voltage:
Current:
Bat.Res.:
Mode:
Status:
Capacity:
Temp:
LiIon
Charge
28 mAh
28
00:01:54
4.35V
0.86A
267mΩ
V
T
Details
AA
1
Back
15:53
Revo
AA
AA
1 3 4
4.40
4.26
4.12
3.68
3.84
3.70
Time:
Voltage:
Current:
Bat.Res.:
Mode:
Status:
Capacity:
Temp:
LiIon
Charge
31 mAh
29
00:01:59
4.32V
1.00A
236mΩ
V
T
Details
AA
2
Back
15:53
Revo
AA
AA
AA
AA