Instructions

15 ·
T200
Lithium Battery Program (LiPo/LiFe/Lilon/LiHV)
VARIOUS INFORMATION DURING THE PROCESS
Press INC or DEC during the charging or discharging process to view further
pertinent information on the LCD screen.
Lp3s 1.5A 12.14V
BAL 000:50 00022
4.07 4.06 4.11 V
0.00 0.00 0.00 V
Fuel= 90%
Cell= 4.10V
INC
INC
Lp3s 1.5A 12.14V
BAL 000:50 00022
Ext. Temp ----
Int. Temp 37°C
DEC
Temp Cut-Off
    50C
DEC
Final voltage when the program ends.
Input voltage.
Safety timer ON and duration of time in minutes.
Capacity cut-off ON and value of the set capacity limit.
Voltage of each cell in the battery pack when the battery is
connected with balance lead.
Internal temperature.
Temperature probe needs to be connected to show
external temperature.
Charged capacity percentage and average cell voltage of
the battery pack.
Real-time status: battery type, battery cell count, charge
current, battery pack total voltage,working mode, elapsed
time and charged capacity.
Cut-off temperature.
DEC
DEC
DEC
DEC
End Voltage
12.6V(3S)
IN Power Voltage
12.56V
Safety Timer
ON 200min
Capacity Cut-Off
ON 5000mAh