User's Manual

Skytech 3001
REV 12/01
Page 6 of 8
HEARTH MOUNT
The remote receiver can be placed on the fireplace hearth or under the fireplace, behind the control access panel. Position where the ambient
temperature inside the receiver case does not exceed 130
0
F
.
NOTE: Black Slide Button is used for Hearth Mount applications.
WIRING INSTRUCTIONS
A qualified electrician or a gas technician who is familiar with the gas appliance and gas valves that will be operated by this remote should
install the remote control system. Incorrect wiring connections
WILL
cause damage to the gas valve or electronic module operating the gas
appliance and may also damage the remote receiver.
WIRING MILLIVOLT VALVES
The remote receiver is connected to the millivolt valve using the TH (thermostat) terminals on the terminal block on the millivolt gas valve.
Connect 18 gauge stranded or solid wires from the remote receiver to the gas valve.
Operation of the remote receiver is similar to that of a thermostat in that both turn the gas valve on and off
based on input signals. A thermostat’s input signals are different temperatures. The remote receiver’s input
signals come from the transmitter.
Connect each of the two wires leading from the TH and TH/TP terminals on the millivolt gas valve to either
of the two wire terminals on the remote receiver. Normally it does not matter which wires go to which
terminal.
WIRING ELECTRONIC SPARK IGNITIONS
The remote control receiver can be connected, in series, to a 24VAC transformer to the TR (transformer)
terminal on the ELECTRONIC MODULE. Connect the hot wire from the 24VAC transformer to either of the
wire terminals on the remote receiver. Connect another wire (not included) between the other receiver wire
terminal and the TH (thermostat) terminal on the ELECTRONIC MODULE.
SYSTEM CHECK
MILLIVOLT VALVES
Light your gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is on; it must be in
operation for the main gas valve to operate.
Slide the 3-position button on the remote receiver to the ON position. The main gas flame (i.e., the fire) should ignite.
Slide the button to OFF. The flame should extinguish (the pilot flame will remain on).
Slide the button to REMOTE (the center position), then press the MODE button on the transmitter to change the system to ON. The main
gas flame should ignite.
Press the MODE button on the transmitter to change the system to OFF. The flame should extinguish (the pilot flame will remain on).
Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to a
temperature of a least 2
0
F (1
0
C) above the ROOM temperature displayed on the LCD screen. With this manual setting, the normal
thermostatic cycle is overridden and the system flame will ignite. Set the SET temperature to at least 2
0
F (1
0
C) below the room
temperature and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle to on and off thermostatically
approximately every two minutes as the ROOM temperature changes, but only when the temperature differential between ROOM and
SET temperatures differ at least 2
0
F (1
0
C). The 2
0
F differential is the factory setting.
ELECTRONIC IGNITION SYSTEMS
Slide the 3-position button on the remote receiver to the ON position. The spark electrode should begin sparking to ignite the pilot (the
pilot may ignite after only one spark). After the pilot flame is lit, the main gas valve should open and the main gas flam e should ignite.
Slide the button to OFF. The main gas flame and pilot flame should BOTH extinguish.
Slide the button to REMOTE (the center position), then press the MODE button on the transmitter to change the system to ON. The spark
electrode should begin sparking to ignite the pilot. After the pilot is lit, the main gas valve should open and the main gas flame should
ignite.
Press the MODE button on the transmitter to OFF. The main gas flame and pilot flame should BOTH extinguish.
Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to a
temperature of at least 2
0
F (1
0
C) above the ROOM temperature displayed on the LCD screen. With this manual setting the normal
thermostatic cycle is overridden and the system flame will ignite. Set the SET temperature to at least 2
0
F (1
0
C) below the room
temperature and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle to on and off thermostatically