Overview of Primary Product
4
1
⁄2
1
13
⁄1
6
3
3
⁄16
1
17
⁄3
2
1
1
⁄2
1
7
7
⁄8
7
⁄8
1
3
⁄8
2
11
⁄16
Length, ft. 2 - 3
1
⁄2 4 - 5 6 - 8 10 12 - 14
Brackets 23468
O
RDERING DATA
No. 30-75 COMPLETE BASEBOARD
PACKAGE
Contains heating element and
enclosure. Following items included:
expansion cradles, support brackets,
damper vane, 2" wide splice plate
with 5' lengths and longer.
LENGTHS: 2', 3', 3
1
/2', 4', 5', 6', 7', 8',
10', 12'
No. 30-DW ENCLOSURE ONLY
PACKAGE
(All parts and lengths as
No. 30-75 WITHOUT heating element
or expansion cradles.)
N0. E-75
3
/4" ELEMENT ONLY
PACKAGE
Heating element with expansion
cradles; NO enclosure.
LENGTHS: 2', 3', 3
1
/2', 4', 5', 6', 7', 8'
PACKAGING
Each baseboard or enclosure only unit
is individually packed—completely
assembled—in its own Zip-strip carton,
with end flaps clearly marked and
color-coded. See R-01 price list for
packaging of accessories.
HEATING ELEMENT SPECIFICATIONS
:
Furnish and install E-75 baseboard
h
eating element as manufactured by Slant/Fin
C
orporation, consisting of
3
⁄4"
nominal copper
t
ubing, with 2
5
⁄8"
x 2
1
⁄8"
x .009" aluminum fins,
bent to 2
5
⁄16" x 2
1
⁄8", spaced 55 per linear foot. A
flange with four teeth shall be formed on each
fin to increase thermal contact and to space and
lock the fins uniformly in place. One end of each
e
lement tube shall be expanded to receive the
unexpanded end of another, without couplings.
© Slant/Fin Corp. 2012. Printed in U.S.A.412. Publication No. 30-10cv
W
ATER PRESSURE
140˚F 150˚F 160˚F 170˚F 180˚F 190˚F 200˚F 210˚F 215˚F 220˚F
FLOW DROP†
1 GPM 47 320* 380 450 510 580 640 710 770 810 840
4
GPM 525 340* 400 480 540 610 680 750 810 860 890
I=B=R APPROVED HOT WATER RATINGS
F
ine/Line 30 – No. 30-75 baseboard with 3/4" E-75 element.
BTU/hr./ft. with 65˚ entering air
† Millinches per foot.
*Ratings at 140˚F and lower temperatures determined by multiplying 150˚F
rating by the applicable factor specified in Table E in the I=B=R Testing and Rating Standard for Baseboard radiation.
NOTE: Ratings are for element installed as per drawing shown here, with damper open, with expansion cradles. Ratings are based
on active finned length (5" to 6" less than overall length) and include 15% heating effect factor. Use 4 gpm ratings only when flow
is known to be equal to or greater than 4 gpm; otherwise 1 gpm ratings must be used.
SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
BRACKETS PER LENGTH
C
omplete assembly and enclosure only
C
OVER ASSEMBLY SPECIFICATIONS:
F
urnish and install Fine/Line 30-75
b
aseboard cover assembly as manufactured by Slant/Fin Corp. The cover consists of a one-piece
bottom, back and top panel, one-piece front panel and one piece damper vane that are formed
out of galvanized cold rolled steel. Cold rolled steel that is not galvanized is not acceptable. The
g
alvanized steel makes the cover rust resistant. Bottom and top of back panel shall have channels
a
long entire length to receive full-height support brackets. Brackets shall add support to the top of
the rear panel. The factory installed damper vane shall modulate fully and freely, while retaining
any setting through its arc. Damper shall swing in position on damper
p
ivots inserted in die-formed slots towards top of support bracket. Roll formed pivot point is not
a
cceptable. All cover components shall be painted in a Nu-White, thermosetting polyester enamel.
B
rackets shall be die-formed of re-phosphorized cold rolled steel, for rigid bracing and spring
locking. Each length of baseboard shall have a minimum quantity of factory installed brackets per
l
ength of baseboard cover as follows: 2, 3 and 3
1
⁄2'
have 2 brackets; 4 and 5' have 3 brackets; 6, 7
a
nd 8' have 4 brackets; 10' has 6 brackets; 12 and 14' have 8 brackets. Fewer brackets are not
a
cceptable.
Slide-action polypropylene expansion cradles shall protect element bottom and sides from con-
tact with support brackets and cover, allowing free lateral element expansion for noiseless opera-
tion. Cradles shall be installed on heating elements at location of brackets.
®
BOILERS & BASEBOARD
Since 1949
T
h
e
O
n
l
y
N
a
m
e
Y
o
u
W
a
n
t
H
e
a
t
i
n
g
Y
o
u
r
H
o
m
e
END CAP Left end cap
3
3
⁄4"
’
wide, No. 30-LEC
with piano-hinged Right end cap
front panel, closed No. 30-REC
end. For use at
doorways.
WALL TRIM Left wall trim
3
3
⁄4" wide, No. 30-LWT
with piano-hinged Right wall trim
front panel, slotted No. 30-RWT
end. For use at wall
partitions.
INSIDE CORNER 90˚ inside corner
3
3
⁄4" wide No. 30-IC-90
at top, with piano- 135˚ inside corner
hinged, contoured No. 30-IC-135
front panel. 91˚to 179˚field
adaptable inside
corner No. IC-FA
VALVE COVER Left valve cover
8" wide, No. 30-LVC
with extra wide Right valve cover
piano-hinged front No. 30-RVC
panel, closed end. Center valve cover
(30-CVC has open No. 30-CVC
ends.)
ZONE VALVE BOX Left
zone
9
1
⁄2" wide, valve box
9" high, No. 30-LZC
3
1
⁄2"deep, with Right
zone
piano-hinged front valve box
panel. Houses most No. 30-RZC
motorized valves.
FILLER SLEEVE
Cover gaps from 7" filler sleeve
1" to 6" or No. 30-FS-7
1" to 12"
Includes back, 14" filler
sleeve
top and front panels No. 30-FS-14
and damper vane.
SPLICE Splice plate set
PLATE SET No. 30-SP
2" wide. Free
with lengths 5'
and longer.
OUTSIDE
90˚outside corner
CORNER No. 30-OC-90
One-piece unit without 135˚ outside corner
hinged panels. No. 30-OC-135
SOLID
WALL TRIM 2" solid
2" or 4" wall
trim
solid (non-hinged), No. 30-WT-2
with open ends. For 4" solid
use at left or right wall wall
trim
partitions or as one- No. 30-WT-4
piece filler sleeve.
BACK PANEL 90˚ back panel
for inside corner. No. 30-ICBP-90
For neat finish of 135˚ back panel
baseboard interior No. 30-ICBP-135
at corners.
Fine/Line 30 Hinged Accessories