Brochure
Specially designed
support bracket
accomodates return
tubing above the heating
element using standard
fittings.
©Slant/Fin 2010. Printed in U.S.A. 1110. Publication No. BL-10
Ordering data:
COMPLETE BASEBOARD PACKAGE
No. BL-75 (with
3
⁄4" element)
No. BL-50 (with
1
⁄2" element)
Carton contains fully assembled baseboard,
complete with damper vane, heating element
and expansion cradles. 2" splice plate packed
with lengths 5' and over. 10 foot assemblies
contain two separate elements.
LENGTHS: 2', 3', 4', 5', 6', 7', 8', 10'
COLOR: Nu-White baked enamel finish.
No. BL-D ENCLOSURE ONLY PACKAGE
Same as No. BL-75 and BL-50, but WITH-
OUT heating element or expansion cradles.
No. E-75E 3/4" ELEMENT ONLY
No. E-50 1/2" ELEMENT ONLY
Heating element with expansion cradles;
NO enclosure. Packed in individual sleeves.
LENGTHS: 2', 3', 3
1
⁄
2
', 4', 5', 6', 7', 8'
Specifications:
HEATING ELEMENT: Furnish and install
E-75E (E-50) baseboard heating element as
manufactured by Slant/Fin Corp., consisting
of
3
⁄4" or
1
⁄2" nominal copper tubing, with 2
5
⁄8" x
2
1
⁄8" x .009" aluminum fins, bent to 2
19
⁄64" x 2
1
⁄8"
or 2
5
⁄16" x 2
1
⁄8", spaced 56.35 per linear foot (55
per foot for E-50). End fins are of plated steel for
extra ruggedness. Polypropylene expansion cra-
dles shall be clipped to element, centered over
each support bracket, and shall protect element
from contact with support brackets or enclosure.
COVER ASSEMBLY: Furnish and install
BL-75 (BL-50) baseboard cover assembly as
manufactured by Slant/Fin Corp., consisting of
back panel, front panel, damper vane and
support brackets (electro-galvanized), formed
of cold rolled steel. Bottom and top edges of
back panel shall be formed to provide channels
along entire length to receive full-height support
brackets. Damper vane shall modulate fully and
retain any setting through its arc. All cover
components shall be painted in Nu-White
thermosetting polyester enamel.
HINGED END CAP
No. BL-LECH-LEFT
No. BL-RECH-RIGHT
4" wide with piano-
hinged door. Allows
3" adjustment.
NON-HINGED
WALL TRIM
No. BL-WT-4—4"
2" SPLICE PLATE
One piece splice
plate included
free with every
baseboard unit
5' and over.
OUTSIDE CORNER
No. BL-OC-90—90°
No. BL-OC-135—135°
4
3
⁄4" wide (2" at top),
one-piece unit.
INSIDE CORNER
No. BL-IC-90—90°
No. BL-IC-135—135°
3
3
⁄4" wide at top
(2
5
⁄16" for 135°).
FILLER SLEEVE
No. BL-FS-7—7"
No. BL-FS-14—12"
One piece filler sleeve
covers gaps from
1" to 6" or 1" to 10".
Base/Line 2000 hot water baseboard radiation accessories:
Please specify part number and name when ordering.
NON-HINGED
END CAP
No. BL- LECN-LEFT
No. BL-RECN-RIGHT
2" solid metal
4
3
⁄
32
"
1
33
⁄
64
"
7
23
⁄
64
"
2
45
⁄
64
"
1
39
⁄
64
"
1
23
⁄
64
"
2
31
⁄
32
"
1
11
⁄
16
"
VALVE COVER
No. BL-LVC-LEFT
No. BL-RVC-RIGHT
8" wide with piano-
hinged door.
Dimensional and installation data:
Baseboard and all hinged accessories serve either flush or recessed installation.
† End cap width: Non-hinged, 2". Hinged, 4" .
2"
3
3
⁄4"
4"
12" or 7"
4"
SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • www.slantfin.com
Phone: (516) 484-2600 • Fax: (516) 484-5921
In Canada: Slant/Fin Ltd/Ltee, Mississauga, Ontario • www.slantfin.can
C
e
l
e
b
r
a
t
i
n
g
o
v
e
r
6
0
y
e
a
r
s
o
f
h
e
a
t
i
n
g
e
x
c
e
l
l
e
n
c
e
Since 1949
Ratings:
Base/Line 2000 Series
Hot water ratings, BTU/HR per linear ft. with 65°F entering air.
† Millinches per foot. *Ratings at 140˚F and lower temperatures determined by multiplying 150˚F rating by the applicable factor specified in Table E in the I=B=R Testing and Rating
Standard for Baseboard radiation.
NOTE: Ratings are for element installed as per drawing shown in “Dimensional Data” window (open “Dimensional Data” window to view) with damper open, with expansion cradles.
Ratings are based on active finned length (5" to 6" less than overall length)and include 15% heating effect factor. Ratings are also based on 3/4" (BL-75) or 1/2" (BL-50) nominal copper tubing
with 2-5/8" x 2-1/8" x .009" aluminum fins, bent to 2-19/64" x 2-1/8" or 2-5/16" x 2-1/8", spaced 56.35 per linear foot (BL-75) or 55 per linear foot (BL-50) (unpainted). Use 4 gpm ratings only
when flow is known to be equal to or greater than 4 gpm; otherwise, 1 gpm ratings must be used.
WATER PRESSURE
FLOW DROP†
110˚F 120˚F 130˚F 140˚F 150˚F 160˚F 170˚F 180˚F 190˚F 200˚F 210˚F 215˚F
220°F
1 GPM 47 150* 200* 250* 300* 360 430 500 570 630 700 770 810 840
4 GPM 525 160* 210* 260* 320* 380 450 530 600 670 740 810 860 890
1GPM 260 150* 200* 250* 300* 360 430 500 570 630 700 770 810 840
4 GPM 2880 160* 210* 260* 320* 380 450 530 600 670 740 810 860 890
ELEMENT
NO. BL-75
Baseboard with
3/4" element
NO. BL-50
Baseboard with
1/2" element
HOT WATER RATINGS
BTU/HR. per linear ft. with 65˚F entering air